CVE-2017-13996

HighCVSS 8.8/10Last modified Jun 17, 2026

Description

A Relative Path Traversal issue was discovered in LOYTEC LVIS-3ME versions prior to 6.2.0. The web user interface fails to prevent access to critical files that non administrative users should not have access to, which could allow an attacker to create or modify files or execute arbitrary code.

Metrics

CVSS 3.0 8.8/10CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Oct 5, 2017
Last modified
Jun 17, 2026
NVD status
Modified

Related CVEs from 2017

CVE-2017-139979.8A Missing Authentication for Critical Function issue was discovered in Schneider Electric InduSoft Web Studio v8.0 SP2 or prior, and InTouchCVE-2017-139987.5An Insufficiently Protected Credentials issue was discovered in LOYTEC LVIS-3ME versions prior to 6.2.0. The application does not sufficientCVE-2017-139999.8A Stack-based Buffer Overflow issue was discovered in WECON LEVI Studio HMI Editor v1.8.1 and prior. Multiple stack-based buffer overflow vuCVE-2017-140009.4An Improper Authentication issue was discovered in Ctek SkyRouter Series 4200 and 4400, all versions prior to V6.00.11. By accessing a speciCVE-2017-140018.8An Improper Neutralization of Special Elements used in an OS Command issue was discovered in Digium Asterisk GUI 2.1.0 and prior. An OS commCVE-2017-140029.8GE Infinia/Infinia with Hawkeye 4 medical imaging systems all current versions are affected these devices use default or hard-coded credentiCVE-2017-140039.8An Authentication Bypass by Spoofing issue was discovered in LAVA Ether-Serial Link (ESL) running firmware versions 6.01.00/29.03.2007 and pCVE-2017-140049.8GE GEMNet License server (EchoServer) all current versions are affected these devices use default or hard-coded credentials. Successful explCVE-2017-140058.8An Unverified Password Change issue was discovered in ProMinent MultiFLEX M10a Controller web interface. When setting a new password for a uCVE-2017-140069.8GE Xeleris versions 1.0,1.1,2.1,3.0,3.1, medical imaging systems, all current versions are affected, these devices use default or hard-codedCVE-2017-140075.6An Insufficient Session Expiration issue was discovered in ProMinent MultiFLEX M10a Controller web interface. The user's session is availablCVE-2017-140089.8GE Centricity PACS RA1000, diagnostic image analysis, all current versions are affected these devices use default or hard-coded credentials.
CVE-2017-13996: High severity, CVSS 8.8 | Vulnix