CVE-2017-14005

HighCVSS 8.8/10Last modified Jun 17, 2026

Description

An Unverified Password Change issue was discovered in ProMinent MultiFLEX M10a Controller web interface. When setting a new password for a user, the application does not require the user to know the original password. An attacker who is authenticated could change a user's password, enabling future access and possible configuration changes.

Metrics

CVSS 3.0 8.8/10CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Oct 17, 2017
Last modified
Jun 17, 2026
NVD status
Modified

Related CVEs from 2017

CVE-2017-140069.8GE Xeleris versions 1.0,1.1,2.1,3.0,3.1, medical imaging systems, all current versions are affected, these devices use default or hard-codedCVE-2017-140075.6An Insufficient Session Expiration issue was discovered in ProMinent MultiFLEX M10a Controller web interface. The user's session is availablCVE-2017-140089.8GE Centricity PACS RA1000, diagnostic image analysis, all current versions are affected these devices use default or hard-coded credentials.CVE-2017-140096.5An Information Exposure issue was discovered in ProMinent MultiFLEX M10a Controller web interface. When an authenticated user uses the ChangCVE-2017-140107.8In SpiderControl MicroBrowser Windows XP, Vista 7, 8 and 10, Versions 1.6.30.144 and prior, an uncontrolled search path element vulnerabilitCVE-2017-140118.8A Cross-Site Request Forgery issue was discovered in ProMinent MultiFLEX M10a Controller web interface. The application does not sufficientlCVE-2017-140124.6Boston Scientific ZOOM LATITUDE PRM Model 3120 does not encrypt PHI at rest. CVSS v3 base score: 4.6; CVSS vector string: AV:P/AC:L/PR:N/UI:CVE-2017-140135.6A Client-Side Enforcement of Server-Side Security issue was discovered in ProMinent MultiFLEX M10a Controller web interface. The log out funCVE-2017-140144.6Boston Scientific ZOOM LATITUDE PRM Model 3120 uses a hard-coded cryptographic key to encrypt PHI prior to having it transferred to removablCVE-2017-140166.3A Stack-based Buffer Overflow issue was discovered in Advantech WebAccess versions prior to V8.2_20170817. The application lacks proper valiCVE-2017-140177.8An Uncontrolled Search Path Element issue was discovered in Progea Movicon Version 11.5.1181 and prior. An uncontrolled search path element CVE-2017-140184.8An improper authentication issue was discovered in Johnson & Johnson Ethicon Endo-Surgery Generator Gen11, all versions released before Nove
CVE-2017-14005: High severity, CVSS 8.8 | Vulnix