CVE-2017-13997

CriticalCVSS 9.8/10Last modified Jun 17, 2026

Description

A Missing Authentication for Critical Function issue was discovered in Schneider Electric InduSoft Web Studio v8.0 SP2 or prior, and InTouch Machine Edition v8.0 SP2 or prior. InduSoft Web Studio provides the capability for an HMI client to trigger script execution on the server for the purposes of performing customized calculations or actions. A remote malicious entity could bypass the server authentication and trigger the execution of an arbitrary command. The command is executed under high privileges and could lead to a complete compromise of the server.

Metrics

CVSS 3.0 9.8/10CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Oct 3, 2017
Last modified
Jun 17, 2026
NVD status
Modified

Related CVEs from 2017

CVE-2017-139987.5An Insufficiently Protected Credentials issue was discovered in LOYTEC LVIS-3ME versions prior to 6.2.0. The application does not sufficientCVE-2017-139999.8A Stack-based Buffer Overflow issue was discovered in WECON LEVI Studio HMI Editor v1.8.1 and prior. Multiple stack-based buffer overflow vuCVE-2017-140009.4An Improper Authentication issue was discovered in Ctek SkyRouter Series 4200 and 4400, all versions prior to V6.00.11. By accessing a speciCVE-2017-140018.8An Improper Neutralization of Special Elements used in an OS Command issue was discovered in Digium Asterisk GUI 2.1.0 and prior. An OS commCVE-2017-140029.8GE Infinia/Infinia with Hawkeye 4 medical imaging systems all current versions are affected these devices use default or hard-coded credentiCVE-2017-140039.8An Authentication Bypass by Spoofing issue was discovered in LAVA Ether-Serial Link (ESL) running firmware versions 6.01.00/29.03.2007 and pCVE-2017-140049.8GE GEMNet License server (EchoServer) all current versions are affected these devices use default or hard-coded credentials. Successful explCVE-2017-140058.8An Unverified Password Change issue was discovered in ProMinent MultiFLEX M10a Controller web interface. When setting a new password for a uCVE-2017-140069.8GE Xeleris versions 1.0,1.1,2.1,3.0,3.1, medical imaging systems, all current versions are affected, these devices use default or hard-codedCVE-2017-140075.6An Insufficient Session Expiration issue was discovered in ProMinent MultiFLEX M10a Controller web interface. The user's session is availablCVE-2017-140089.8GE Centricity PACS RA1000, diagnostic image analysis, all current versions are affected these devices use default or hard-coded credentials.CVE-2017-140096.5An Information Exposure issue was discovered in ProMinent MultiFLEX M10a Controller web interface. When an authenticated user uses the Chang
CVE-2017-13997: Critical severity, CVSS 9.8 | Vulnix