An Improper Neutralization of Special Elements used in an OS Command issue was discovered in Digium Asterisk GUI 2.1.0 and prior. An OS command injection vulnerability has been identified that may allow the execution of arbitrary code on the system through the inclusion of OS commands in the URL request of the program.

Metrics

CVSS 3.0 8.8/10CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Sep 26, 2017
Last modified
Jun 17, 2026
NVD status
Modified

Related CVEs from 2017

CVE-2017-140029.8GE Infinia/Infinia with Hawkeye 4 medical imaging systems all current versions are affected these devices use default or hard-coded credentiCVE-2017-140039.8An Authentication Bypass by Spoofing issue was discovered in LAVA Ether-Serial Link (ESL) running firmware versions 6.01.00/29.03.2007 and pCVE-2017-140049.8GE GEMNet License server (EchoServer) all current versions are affected these devices use default or hard-coded credentials. Successful explCVE-2017-140058.8An Unverified Password Change issue was discovered in ProMinent MultiFLEX M10a Controller web interface. When setting a new password for a uCVE-2017-140069.8GE Xeleris versions 1.0,1.1,2.1,3.0,3.1, medical imaging systems, all current versions are affected, these devices use default or hard-codedCVE-2017-140075.6An Insufficient Session Expiration issue was discovered in ProMinent MultiFLEX M10a Controller web interface. The user's session is availablCVE-2017-140089.8GE Centricity PACS RA1000, diagnostic image analysis, all current versions are affected these devices use default or hard-coded credentials.CVE-2017-140096.5An Information Exposure issue was discovered in ProMinent MultiFLEX M10a Controller web interface. When an authenticated user uses the ChangCVE-2017-140107.8In SpiderControl MicroBrowser Windows XP, Vista 7, 8 and 10, Versions 1.6.30.144 and prior, an uncontrolled search path element vulnerabilitCVE-2017-140118.8A Cross-Site Request Forgery issue was discovered in ProMinent MultiFLEX M10a Controller web interface. The application does not sufficientlCVE-2017-140124.6Boston Scientific ZOOM LATITUDE PRM Model 3120 does not encrypt PHI at rest. CVSS v3 base score: 4.6; CVSS vector string: AV:P/AC:L/PR:N/UI:CVE-2017-140135.6A Client-Side Enforcement of Server-Side Security issue was discovered in ProMinent MultiFLEX M10a Controller web interface. The log out fun
CVE-2017-14001: High severity, CVSS 8.8 | Vulnix