CVE-2016-8360

HighCVSS 8.1/10Last modified Jun 17, 2026

Description

An issue was discovered in Moxa SoftCMS versions prior to Version 1.6. A specially crafted URL request sent to the SoftCMS ASP Webserver can cause a double free condition on the server allowing an attacker to modify memory locations and possibly cause a denial of service or the execution of arbitrary code.

Metrics

CVSS 3.0 8.1/10CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Feb 13, 2017
Last modified
Jun 17, 2026
NVD status
Modified

Related CVEs from 2016

CVE-2016-83618.6An issue was discovered in Lynxspring JENEsys BAS Bridge versions 1.1.8 and older. The application uses a hard-coded username with no passwoCVE-2016-83626.5An issue was discovered in Moxa OnCell OnCellG3470A-LTE, AWK-1131A/3131A/4131A Series, AWK-3191 Series, AWK-5232/6232 Series, AWK-1121/1127 CVE-2016-836310.0An issue was discovered in Moxa OnCell OnCellG3470A-LTE, AWK-1131A/3131A/4131A Series, AWK-3191 Series, AWK-5232/6232 Series, AWK-1121/1127 CVE-2016-83649.8An issue was discovered in IBHsoftec S7-SoftPLC prior to 4.12b. Object memory can read a network packet that is larger than the space that iCVE-2016-83655.5OSIsoft PI System software (Applications using PI Asset Framework (AF) Client versions prior to PI AF Client 2016, Version 2.8.0; ApplicatioCVE-2016-83667.3Webvisit in Phoenix Contact ILC PLCs offers a password macro to protect HMI pages on the PLC against casual or coincidental opening of HMI pCVE-2016-83675.3An issue was discovered in Schneider Electric Magelis HMI Magelis GTO Advanced Optimum Panels, all versions, Magelis GTU Universal Panel, alCVE-2016-83688.6An issue was discovered in Mitsubishi Electric Automation MELSEC-Q series Ethernet interface modules QJ71E71-100, all versions, QJ71E71-B5, CVE-2016-83698.8An issue was discovered in Lynxspring JENEsys BAS Bridge versions 1.1.8 and older. The application does not sufficiently verify if a requestCVE-2016-83707.5An issue was discovered in Mitsubishi Electric Automation MELSEC-Q series Ethernet interface modules QJ71E71-100, all versions, QJ71E71-B5, CVE-2016-83717.3The web server in Phoenix Contact ILC PLCs can be accessed without authenticating even if the authentication mechanism is enabled.CVE-2016-83728.1An issue was discovered in Moxa ioLogik E1210, firmware Version V2.4 and prior, ioLogik E1211, firmware Version V2.3 and prior, ioLogik E121
CVE-2016-8360: High severity, CVSS 8.1 | Vulnix