Description

An issue was discovered in Moxa OnCell OnCellG3470A-LTE, AWK-1131A/3131A/4131A Series, AWK-3191 Series, AWK-5232/6232 Series, AWK-1121/1127 Series, WAC-1001 V2 Series, WAC-2004 Series, AWK-3121-M12-RTG Series, AWK-3131-M12-RCC Series, AWK-5232-M12-RCC Series, TAP-6226 Series, AWK-3121/4121 Series, AWK-3131/4131 Series, and AWK-5222/6222 Series. Any user is able to download log files by accessing a specific URL.

Metrics

CVSS 3.0 6.5/10CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Feb 13, 2017
Last modified
Jun 17, 2026
NVD status
Modified

Related CVEs from 2016

CVE-2016-836310.0An issue was discovered in Moxa OnCell OnCellG3470A-LTE, AWK-1131A/3131A/4131A Series, AWK-3191 Series, AWK-5232/6232 Series, AWK-1121/1127 CVE-2016-83649.8An issue was discovered in IBHsoftec S7-SoftPLC prior to 4.12b. Object memory can read a network packet that is larger than the space that iCVE-2016-83655.5OSIsoft PI System software (Applications using PI Asset Framework (AF) Client versions prior to PI AF Client 2016, Version 2.8.0; ApplicatioCVE-2016-83667.3Webvisit in Phoenix Contact ILC PLCs offers a password macro to protect HMI pages on the PLC against casual or coincidental opening of HMI pCVE-2016-83675.3An issue was discovered in Schneider Electric Magelis HMI Magelis GTO Advanced Optimum Panels, all versions, Magelis GTU Universal Panel, alCVE-2016-83688.6An issue was discovered in Mitsubishi Electric Automation MELSEC-Q series Ethernet interface modules QJ71E71-100, all versions, QJ71E71-B5, CVE-2016-83698.8An issue was discovered in Lynxspring JENEsys BAS Bridge versions 1.1.8 and older. The application does not sufficiently verify if a requestCVE-2016-83707.5An issue was discovered in Mitsubishi Electric Automation MELSEC-Q series Ethernet interface modules QJ71E71-100, all versions, QJ71E71-B5, CVE-2016-83717.3The web server in Phoenix Contact ILC PLCs can be accessed without authenticating even if the authentication mechanism is enabled.CVE-2016-83728.1An issue was discovered in Moxa ioLogik E1210, firmware Version V2.4 and prior, ioLogik E1211, firmware Version V2.3 and prior, ioLogik E121CVE-2016-83747.5An issue was discovered in Schneider Electric Magelis HMI Magelis GTO Advanced Optimum Panels, all versions, Magelis GTU Universal Panel, alCVE-2016-83754.9An issue was discovered in Becton, Dickinson and Company (BD) Alaris 8015 Point of Care (PC) unit, Version 9.5 and prior versions, and Versi
CVE-2016-8362: Medium severity, CVSS 6.5 | Vulnix