Description

Webvisit in Phoenix Contact ILC PLCs offers a password macro to protect HMI pages on the PLC against casual or coincidental opening of HMI pages by the user. The password macro can be configured in a way that the password is stored and transferred in clear text.

Metrics

CVSS 3.0 7.3/10CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L

Weakness enumeration

Affected software

VendorProductVersions
Phoenix ContactPhoenix Contact ILC PLCsAll ILC 1xx PLCs

References

Timeline

Published
Apr 5, 2018
Last modified
Jun 17, 2026
NVD status
Modified

Related CVEs from 2016

CVE-2016-83675.3An issue was discovered in Schneider Electric Magelis HMI Magelis GTO Advanced Optimum Panels, all versions, Magelis GTU Universal Panel, alCVE-2016-83688.6An issue was discovered in Mitsubishi Electric Automation MELSEC-Q series Ethernet interface modules QJ71E71-100, all versions, QJ71E71-B5, CVE-2016-83698.8An issue was discovered in Lynxspring JENEsys BAS Bridge versions 1.1.8 and older. The application does not sufficiently verify if a requestCVE-2016-83707.5An issue was discovered in Mitsubishi Electric Automation MELSEC-Q series Ethernet interface modules QJ71E71-100, all versions, QJ71E71-B5, CVE-2016-83717.3The web server in Phoenix Contact ILC PLCs can be accessed without authenticating even if the authentication mechanism is enabled.CVE-2016-83728.1An issue was discovered in Moxa ioLogik E1210, firmware Version V2.4 and prior, ioLogik E1211, firmware Version V2.3 and prior, ioLogik E121CVE-2016-83747.5An issue was discovered in Schneider Electric Magelis HMI Magelis GTO Advanced Optimum Panels, all versions, Magelis GTU Universal Panel, alCVE-2016-83754.9An issue was discovered in Becton, Dickinson and Company (BD) Alaris 8015 Point of Care (PC) unit, Version 9.5 and prior versions, and VersiCVE-2016-83766.1An issue was discovered in Kabona AB WebDatorCentral (WDC) application prior to Version 3.4.0. This non-validated redirect/non-validated forCVE-2016-83778.0An issue was discovered in Fatek Automation PLC WinProladder Version 3.11 Build 14701. A stack-based buffer overflow vulnerability exists whCVE-2016-83789.8An issue was discovered in Lynxspring JENEsys BAS Bridge versions 1.1.8 and older. The application's database lacks sufficient safeguards foCVE-2016-83798.1An issue was discovered in Moxa ioLogik E1210, firmware Version V2.4 and prior, ioLogik E1211, firmware Version V2.3 and prior, ioLogik E121
CVE-2016-8366: High severity, CVSS 7.3 | Vulnix