CVE-2016-8367

MediumCVSS 5.3/10Last modified Jun 17, 2026

Description

An issue was discovered in Schneider Electric Magelis HMI Magelis GTO Advanced Optimum Panels, all versions, Magelis GTU Universal Panel, all versions, Magelis STO5xx and STU Small panels, all versions, Magelis XBT GH Advanced Hand-held Panels, all versions, Magelis XBT GK Advanced Touchscreen Panels with Keyboard, all versions, Magelis XBT GT Advanced Touchscreen Panels, all versions, and Magelis XBT GTW Advanced Open Touchscreen Panels (Windows XPe). An attacker can open multiple connections to a targeted web server and keep connections open preventing new connections from being made, rendering the web server unavailable during an attack.

Metrics

CVSS 3.1 5.3/10CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Feb 13, 2017
Last modified
Jun 17, 2026
NVD status
Modified

Related CVEs from 2016

CVE-2016-83688.6An issue was discovered in Mitsubishi Electric Automation MELSEC-Q series Ethernet interface modules QJ71E71-100, all versions, QJ71E71-B5, CVE-2016-83698.8An issue was discovered in Lynxspring JENEsys BAS Bridge versions 1.1.8 and older. The application does not sufficiently verify if a requestCVE-2016-83707.5An issue was discovered in Mitsubishi Electric Automation MELSEC-Q series Ethernet interface modules QJ71E71-100, all versions, QJ71E71-B5, CVE-2016-83717.3The web server in Phoenix Contact ILC PLCs can be accessed without authenticating even if the authentication mechanism is enabled.CVE-2016-83728.1An issue was discovered in Moxa ioLogik E1210, firmware Version V2.4 and prior, ioLogik E1211, firmware Version V2.3 and prior, ioLogik E121CVE-2016-83747.5An issue was discovered in Schneider Electric Magelis HMI Magelis GTO Advanced Optimum Panels, all versions, Magelis GTU Universal Panel, alCVE-2016-83754.9An issue was discovered in Becton, Dickinson and Company (BD) Alaris 8015 Point of Care (PC) unit, Version 9.5 and prior versions, and VersiCVE-2016-83766.1An issue was discovered in Kabona AB WebDatorCentral (WDC) application prior to Version 3.4.0. This non-validated redirect/non-validated forCVE-2016-83778.0An issue was discovered in Fatek Automation PLC WinProladder Version 3.11 Build 14701. A stack-based buffer overflow vulnerability exists whCVE-2016-83789.8An issue was discovered in Lynxspring JENEsys BAS Bridge versions 1.1.8 and older. The application's database lacks sufficient safeguards foCVE-2016-83798.1An issue was discovered in Moxa ioLogik E1210, firmware Version V2.4 and prior, ioLogik E1211, firmware Version V2.3 and prior, ioLogik E121CVE-2016-83807.3The web server in Phoenix Contact ILC PLCs allows access to read and write PLC variables without authentication.
CVE-2016-8367: Medium severity, CVSS 5.3 | Vulnix