CVE-2025-54485

CriticalCVSS 9.8/10Last modified Jun 17, 2026

Description

A stack-based buffer overflow vulnerability exists in the MFER parsing functionality of The Biosig Project libbiosig 3.9.0 and Master Branch (35a819fa). A specially crafted MFER file can lead to arbitrary code execution. An attacker can provide a malicious file to trigger this vulnerability.This vulnerability manifests on line 8785 of biosig.c on the current master branch (35a819fa), when the Tag is 8: else if (tag==8) { if (len>2) fprintf(stderr,"Warning MFER tag8 incorrect length %i>2\n",len); curPos += ifread(buf,1,len,hdr);

Metrics

CVSS 3.1 9.8/10CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Aug 25, 2025
Last modified
Jun 17, 2026
NVD status
Modified

Related CVEs from 2025

CVE-2025-544869.8A stack-based buffer overflow vulnerability exists in the MFER parsing functionality of The Biosig Project libbiosig 3.9.0 and Master BranchCVE-2025-544879.8A stack-based buffer overflow vulnerability exists in the MFER parsing functionality of The Biosig Project libbiosig 3.9.0 and Master BranchCVE-2025-544889.8A stack-based buffer overflow vulnerability exists in the MFER parsing functionality of The Biosig Project libbiosig 3.9.0 and Master BranchCVE-2025-544899.8A stack-based buffer overflow vulnerability exists in the MFER parsing functionality of The Biosig Project libbiosig 3.9.0 and Master BranchCVE-2025-54496.5A flaw was found in the SFTP server message decoding logic of libssh. The issue occurs due to an incorrect packet length check that allows aCVE-2025-544909.8A stack-based buffer overflow vulnerability exists in the MFER parsing functionality of The Biosig Project libbiosig 3.9.0 and Master BranchCVE-2025-544919.8A stack-based buffer overflow vulnerability exists in the MFER parsing functionality of The Biosig Project libbiosig 3.9.0 and Master BranchCVE-2025-544929.8A stack-based buffer overflow vulnerability exists in the MFER parsing functionality of The Biosig Project libbiosig 3.9.0 and Master BranchCVE-2025-544939.8A stack-based buffer overflow vulnerability exists in the MFER parsing functionality of The Biosig Project libbiosig 3.9.0 and Master BranchCVE-2025-544949.8A stack-based buffer overflow vulnerability exists in the MFER parsing functionality of The Biosig Project libbiosig 3.9.0 and Master BranchCVE-2025-544955.4A reflected cross-site scripting (xss) vulnerability exists in the emailfailedjob functionality of MedDream PACS Premium 7.3.6.870. A speciaCVE-2025-544967.8A maliciously crafted project file may cause a heap-based buffer overflow in Fuji Electric Monitouch V-SFT-6, which may allow the attacker
CVE-2025-54485: Critical severity, CVSS 9.8 | Vulnix