CVE-2025-54487

CriticalCVSS 9.8/10Last modified Jun 17, 2026

Description

A stack-based buffer overflow vulnerability exists in the MFER parsing functionality of The Biosig Project libbiosig 3.9.0 and Master Branch (35a819fa). A specially crafted MFER file can lead to arbitrary code execution. An attacker can provide a malicious file to trigger this vulnerability.This vulnerability manifests on line 8842 of biosig.c on the current master branch (35a819fa), when the Tag is 12: else if (tag==12) //0x0C { // sampling resolution if (len>6) fprintf(stderr,"Warning MFER tag12 incorrect length %i>6\n",len); val32 = 0; int8_t v8; curPos += ifread(&UnitCode,1,1,hdr); curPos += ifread(&v8,1,1,hdr); curPos += ifread(buf,1,len-2,hdr); In addition to values of `len` greater than 130 triggering a buffer overflow, a value of `len` smaller than 2 will also trigger a buffer overflow due to an integer underflow when computing `len-2` in this code path.

Metrics

CVSS 3.1 9.8/10CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Aug 25, 2025
Last modified
Jun 17, 2026
NVD status
Modified

Related CVEs from 2025

CVE-2025-544889.8A stack-based buffer overflow vulnerability exists in the MFER parsing functionality of The Biosig Project libbiosig 3.9.0 and Master BranchCVE-2025-544899.8A stack-based buffer overflow vulnerability exists in the MFER parsing functionality of The Biosig Project libbiosig 3.9.0 and Master BranchCVE-2025-54496.5A flaw was found in the SFTP server message decoding logic of libssh. The issue occurs due to an incorrect packet length check that allows aCVE-2025-544909.8A stack-based buffer overflow vulnerability exists in the MFER parsing functionality of The Biosig Project libbiosig 3.9.0 and Master BranchCVE-2025-544919.8A stack-based buffer overflow vulnerability exists in the MFER parsing functionality of The Biosig Project libbiosig 3.9.0 and Master BranchCVE-2025-544929.8A stack-based buffer overflow vulnerability exists in the MFER parsing functionality of The Biosig Project libbiosig 3.9.0 and Master BranchCVE-2025-544939.8A stack-based buffer overflow vulnerability exists in the MFER parsing functionality of The Biosig Project libbiosig 3.9.0 and Master BranchCVE-2025-544949.8A stack-based buffer overflow vulnerability exists in the MFER parsing functionality of The Biosig Project libbiosig 3.9.0 and Master BranchCVE-2025-544955.4A reflected cross-site scripting (xss) vulnerability exists in the emailfailedjob functionality of MedDream PACS Premium 7.3.6.870. A speciaCVE-2025-544967.8A maliciously crafted project file may cause a heap-based buffer overflow in Fuji Electric Monitouch V-SFT-6, which may allow the attackerCVE-2025-544978.1Cognex In-Sight Explorer and In-Sight Camera Firmware expose a telnet-based service on port 23 to allow management operations such as firmCVE-2025-544993.7Mattermost versions 10.5.x <= 10.5.10, 10.11.x <= 10.11.2 fail to use constant-time comparison for sensitive string comparisons which allows
CVE-2025-54487: Critical severity, CVSS 9.8 | Vulnix