CVE-2025-54489

CriticalCVSS 9.8/10Last modified Jun 17, 2026

Description

A stack-based buffer overflow vulnerability exists in the MFER parsing functionality of The Biosig Project libbiosig 3.9.0 and Master Branch (35a819fa). A specially crafted MFER file can lead to arbitrary code execution. An attacker can provide a malicious file to trigger this vulnerability.This vulnerability manifests on line 8970 of biosig.c on the current master branch (35a819fa), when the Tag is 63: else if (tag==63) { uint8_t tag2=255, len2=255; count = 0; while ((count<len) && !(FlagInfiniteLength && len2==0 && tag2==0)){ curPos += ifread(&tag2,1,1,hdr); curPos += ifread(&len2,1,1,hdr); if (VERBOSE_LEVEL==9) fprintf(stdout,"MFER: tag=%3i chan=%2i len=%-4i tag2=%3i len2=%3i curPos=%i %li count=%4i\n",tag,chan,len,tag2,len2,curPos,iftell(hdr),(int)count); if (FlagInfiniteLength && len2==0 && tag2==0) break; count += (2+len2); curPos += ifread(&buf,1,len2,hdr); Here, the number of bytes read is not the Data Length decoded from the current frame in the file (`len`) but rather is a new length contained in a single octet read from the same input file (`len2`). Despite this, a stack-based buffer overflow condition can still occur, as the destination buffer is still `buf`, which has a size of only 128 bytes, while `len2` can be as large as 255.

Metrics

CVSS 3.1 9.8/10CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Aug 25, 2025
Last modified
Jun 17, 2026
NVD status
Modified

Related CVEs from 2025

CVE-2025-54496.5A flaw was found in the SFTP server message decoding logic of libssh. The issue occurs due to an incorrect packet length check that allows aCVE-2025-544909.8A stack-based buffer overflow vulnerability exists in the MFER parsing functionality of The Biosig Project libbiosig 3.9.0 and Master BranchCVE-2025-544919.8A stack-based buffer overflow vulnerability exists in the MFER parsing functionality of The Biosig Project libbiosig 3.9.0 and Master BranchCVE-2025-544929.8A stack-based buffer overflow vulnerability exists in the MFER parsing functionality of The Biosig Project libbiosig 3.9.0 and Master BranchCVE-2025-544939.8A stack-based buffer overflow vulnerability exists in the MFER parsing functionality of The Biosig Project libbiosig 3.9.0 and Master BranchCVE-2025-544949.8A stack-based buffer overflow vulnerability exists in the MFER parsing functionality of The Biosig Project libbiosig 3.9.0 and Master BranchCVE-2025-544955.4A reflected cross-site scripting (xss) vulnerability exists in the emailfailedjob functionality of MedDream PACS Premium 7.3.6.870. A speciaCVE-2025-544967.8A maliciously crafted project file may cause a heap-based buffer overflow in Fuji Electric Monitouch V-SFT-6, which may allow the attackerCVE-2025-544978.1Cognex In-Sight Explorer and In-Sight Camera Firmware expose a telnet-based service on port 23 to allow management operations such as firmCVE-2025-544993.7Mattermost versions 10.5.x <= 10.5.10, 10.11.x <= 10.11.2 fail to use constant-time comparison for sensitive string comparisons which allowsCVE-2025-54502.7Improper access control in the certificate management component of Ivanti Connect Secure before version 22.7R2.8 and Ivanti Policy Secure beCVE-2025-545005.3An HTTP/2 implementation flaw allows a denial-of-service (DoS) that uses malformed HTTP/2 control frames in order to break the max concurren
CVE-2025-54489: Critical severity, CVSS 9.8 | Vulnix