CVE-2022-30262

HighCVSS 7.8/10Last modified Jun 17, 2026

Description

The Emerson ControlWave 'Next Generation' RTUs through 2022-05-02 mishandle firmware integrity. They utilize the BSAP-IP protocol to transmit firmware updates. Firmware updates are supplied as CAB archive files containing a binary firmware image. In all cases, firmware images were found to have no authentication (in the form of firmware signing) and only relied on insecure checksums for regular integrity checks.

Metrics

CVSS 3.1 7.8/10CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Aug 17, 2022
Last modified
Jun 17, 2026
NVD status
Modified

Related CVEs from 2022

CVE-2022-302649.8The Emerson ROC and FloBoss RTU product lines through 2022-05-02 perform insecure filesystem operations. They utilize the ROC protocol (4000CVE-2022-302698.8Motorola ACE1000 RTUs through 2022-05-02 mishandle application integrity. They allow for custom application installation via either STS softCVE-2022-30275.7The CMS8000 device does not properly control or sanitize the SSID name of a new Wi-Fi access point. A threat actor could create an SSID withCVE-2022-302709.8The Motorola ACE1000 RTU through 2022-05-02 has default credentials. It exposes an SSH interface on port 22/TCP. This interface is used for CVE-2022-302719.8The Motorola ACE1000 RTU through 2022-05-02 ships with a hardcoded SSH private key and initialization scripts (such as /etc/init.d/sshd_servCVE-2022-302727.2The Motorola ACE1000 RTU through 2022-05-02 mishandles firmware integrity. It utilizes either the STS software suite or ACE1000 Easy ConfiguCVE-2022-302739.8The Motorola MDLC protocol through 2022-05-02 mishandles message integrity. It supports three security modes: Plain, Legacy Encryption, and CVE-2022-302749.8The Motorola ACE1000 RTU through 2022-05-02 uses ECB encryption unsafely. It can communicate with an XRT LAN-to-radio gateway by means of anCVE-2022-302757.5The Motorola MOSCAD Toolbox software through 2022-05-02 relies on a cleartext password. It utilizes an MDLC driver to communicate with MOSCACVE-2022-302767.5The Motorola MOSCAD and ACE line of RTUs through 2022-05-02 omit an authentication requirement. They feature IP Gateway modules which allow CVE-2022-302775.7BD Synapsys™, versions 4.20, 4.20 SR1, and 4.30, contain an insufficient session expiration vulnerability. If exploited, threat actors may bCVE-2022-302786.1A vulnerability in Black Duck Hub’s embedded MadCap Flare documentation files could allow an unauthenticated remote attacker to conduct a cr
CVE-2022-30262: High severity, CVSS 7.8 | Vulnix