CVE-2020-25178

HighCVSS 8.8/10Last modified Jun 17, 2026

Description

ISaGRAF Workbench communicates with Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x using TCP/IP. This communication protocol provides various file system operations, as well as the uploading of applications. Data is transferred over this protocol unencrypted, which could allow a remote unauthenticated attacker to upload, read, and delete files.

Metrics

CVSS 3.1 8.8/10CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Mar 18, 2022
Last modified
Jun 17, 2026
NVD status
Modified

Related CVEs from 2020

CVE-2020-251799.8GE Healthcare Imaging and Ultrasound Products may allow specific credentials to be exposed during transport over the network.CVE-2020-25187.5Vulnerability in the Java VM component of Oracle Database Server. Supported versions that are affected are 11.2.0.4, 12.1.0.2, 12.2.0.1, 18cCVE-2020-251806.5Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x includes the functionality of setting a password that is required to execute privilCVE-2020-251818.8WECON PLC Editor Versions 1.3.8 and prior has a heap-based buffer overflow vulnerabilities have been identified that may allow arbitrary codCVE-2020-251826.7Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x searches for and loads DLLs as dynamic libraries. Uncontrolled loading of dynamic lCVE-2020-251838.8Medtronic MyCareLink Smart 25000 contains an authentication protocol vulnerability where the method used to authenticate between the MCL SCVE-2020-251845.5Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x stores the password in plaintext in a file that is in the same directory as the exeCVE-2020-251858.8The affected product is vulnerable to five post-authentication buffer overflows, which may allow a logged in user to remotely execute arbitrCVE-2020-251867.5An XXE vulnerability exists within LeviStudioU Release Build 2019-09-21 and prior when processing parameter entities, which may allow file dCVE-2020-251879.8Medtronic MyCareLink Smart 25000 is  vulnerable when an authenticated attacker runs a debug command, which can be sent to the patient readCVE-2020-251887.8An attacker who convinces a valid user to open a specially crafted project file to exploit could execute code under the privileges of the apCVE-2020-251899.8The affected product is vulnerable to three stack-based buffer overflows, which may allow an unauthenticated attacker to remotely execute ar
CVE-2020-25178: High severity, CVSS 8.8 | Vulnix