CVE-2020-25179

CriticalCVSS 9.8/10Last modified Jun 17, 2026

Description

GE Healthcare Imaging and Ultrasound Products may allow specific credentials to be exposed during transport over the network.

Metrics

CVSS 3.1 9.8/10CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Weakness enumeration

Affected software

VendorProductVersions
n/aGE Healthcare Imaging and Ultrasound ProductsMR 3.0T Signa HDxt / 3.0T Signa HDx, versions HD 16, HD23 1.5T Brivo MR355 / Optima MR360, versions SV20.1, SV23.0 1.5T Signa HDx / 1.5T Signa HDx, Signa HDi / Signa VIBRANT, versions HD16, HD23 Ultrasound, General Imaging LOGIQ 5 [BT03], LOGIQ 7 (BT03, BT04, BT06], LOGIQ 9 [BT02, BT03, BT04, BT06] Ultrasound, Cardiovascular Vivid I [BT06], Vivid 7 {BT02-BT06], EchoPAC (Turnkey) [BT06], Image Vault (Turnkey) [4.3] Ultrasound, Women’s Health Voluson 730 [BT05, BT08] Advanced Visualization AW 4.0 to AW 4.6, AWS2.0 to AW3.0 , Interventional Innova 2000, 3100, 4100, 2100-IQ, 3100-IQ, 4100-IQ, 212-IQ, 313-IQ Optima 320, CL320i, CL323i, CL320, 3100 Optima IGS 320, 330; Innova IGS 5x0, 6x0, 7x0 Advanced Visualization AW 4.0 to AW 4.6, AWS2.0 to AW3.0 X-Ray Brivo XR118, XR383, XR515, XR575; Definium 5000, 6000, 8000, AMX 700; Discovery XR650, XR656, XR656+; Optima XR640, XR646, XR220amx, XR200amx; Precision 500D, WDR1 Mammography Seno 200D, DS, Essential; Senographe Pristina Computed Tomography BrightSpeed Elite, Elite Select, Edge, Edge Select Brivo CT385 Discovery CT590RT, CT750HD LightSpeed VCT, Pro16, RT16 Optima Advance, CT520, CT540, CT660, CT580, CT580RT, CT580W, CT670, CT680 Quantum, Expert & Professional Revolution EVO,HD,ACT, ACTs, CT, Discovery CT, Frontier, Frontier ES Nuclear Medicine, PET/CT Brivo NM 615 Discovery NM 630, NM 750b, NM D530c, NM/CT D570c, NM/CT 670 Infinia Discovery NM830, NM/CT 860, NM/CT850, NM/CT 870

References

Timeline

Published
Dec 14, 2020
Last modified
Jun 17, 2026
NVD status
Modified

Related CVEs from 2020

CVE-2020-25187.5Vulnerability in the Java VM component of Oracle Database Server. Supported versions that are affected are 11.2.0.4, 12.1.0.2, 12.2.0.1, 18cCVE-2020-251806.5Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x includes the functionality of setting a password that is required to execute privilCVE-2020-251818.8WECON PLC Editor Versions 1.3.8 and prior has a heap-based buffer overflow vulnerabilities have been identified that may allow arbitrary codCVE-2020-251826.7Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x searches for and loads DLLs as dynamic libraries. Uncontrolled loading of dynamic lCVE-2020-251838.8Medtronic MyCareLink Smart 25000 contains an authentication protocol vulnerability where the method used to authenticate between the MCL SCVE-2020-251845.5Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x stores the password in plaintext in a file that is in the same directory as the exeCVE-2020-251858.8The affected product is vulnerable to five post-authentication buffer overflows, which may allow a logged in user to remotely execute arbitrCVE-2020-251867.5An XXE vulnerability exists within LeviStudioU Release Build 2019-09-21 and prior when processing parameter entities, which may allow file dCVE-2020-251879.8Medtronic MyCareLink Smart 25000 is  vulnerable when an authenticated attacker runs a debug command, which can be sent to the patient readCVE-2020-251887.8An attacker who convinces a valid user to open a specially crafted project file to exploit could execute code under the privileges of the apCVE-2020-251899.8The affected product is vulnerable to three stack-based buffer overflows, which may allow an unauthenticated attacker to remotely execute arCVE-2020-25194.3Vulnerability in the Oracle WebLogic Server product of Oracle Fusion Middleware (component: Console). Supported versions that are affected a
CVE-2020-25179: Critical severity, CVSS 9.8 | Vulnix