CVE-2020-25182

MediumCVSS 6.7/10Last modified Jun 17, 2026

Description

Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x searches for and loads DLLs as dynamic libraries. Uncontrolled loading of dynamic libraries could allow a local, unauthenticated attacker to execute arbitrary code. This vulnerability only affects ISaGRAF Runtime when running on Microsoft Windows systems.

Metrics

CVSS 3.1 6.7/10CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Mar 18, 2022
Last modified
Jun 17, 2026
NVD status
Modified

Related CVEs from 2020

CVE-2020-251838.8Medtronic MyCareLink Smart 25000 contains an authentication protocol vulnerability where the method used to authenticate between the MCL SCVE-2020-251845.5Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x stores the password in plaintext in a file that is in the same directory as the exeCVE-2020-251858.8The affected product is vulnerable to five post-authentication buffer overflows, which may allow a logged in user to remotely execute arbitrCVE-2020-251867.5An XXE vulnerability exists within LeviStudioU Release Build 2019-09-21 and prior when processing parameter entities, which may allow file dCVE-2020-251879.8Medtronic MyCareLink Smart 25000 is  vulnerable when an authenticated attacker runs a debug command, which can be sent to the patient readCVE-2020-251887.8An attacker who convinces a valid user to open a specially crafted project file to exploit could execute code under the privileges of the apCVE-2020-251899.8The affected product is vulnerable to three stack-based buffer overflows, which may allow an unauthenticated attacker to remotely execute arCVE-2020-25194.3Vulnerability in the Oracle WebLogic Server product of Oracle Fusion Middleware (component: Console). Supported versions that are affected aCVE-2020-251909.8The built-in WEB server for MOXA NPort IAW5000A-I/O firmware version 2.1 or lower stores and transmits the credentials of third-party servicCVE-2020-251917.5Incorrect permissions are set by default for an API entry-point of a specific service, allowing a non-authenticated user to trigger a functiCVE-2020-251925.3The built-in WEB server for MOXA NPort IAW5000A-I/O firmware version 2.1 or lower allows sensitive information to be displayed without propeCVE-2020-251935.3By having access to the hard-coded cryptographic key for GE Reason RT430, RT431 & RT434 GNSS clocks in firmware versions prior to version 08
CVE-2020-25182: Medium severity, CVSS 6.7 | Vulnix