CVE-2018-13800

HighCVSS 7.3/10Last modified Jun 17, 2026

Description

A vulnerability has been identified in SIMATIC S7-1200 CPU family version 4 (All versions < V4.2.3). The web interface could allow a Cross-Site Request Forgery (CSRF) attack if an unsuspecting user is tricked into accessing a malicious link. Successful exploitation requires user interaction by a legitimate user, who must be authenticated to the web interface. A successful attack could allow an attacker to trigger actions via the web interface that the legitimate user is allowed to perform. This could allow the attacker to read or modify parts of the device configuration.

Metrics

CVSS 3.0 7.3/10CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:N

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Oct 10, 2018
Last modified
Jun 17, 2026
NVD status
Modified

Related CVEs from 2018

CVE-2018-138018.8A vulnerability has been identified in ROX II (All versions < V2.12.1). An attacker with network access to port 22/tcp and valid low-privileCVE-2018-138027.2A vulnerability has been identified in ROX II (All versions < V2.12.1). An authenticated attacker with a high-privileged user account accessCVE-2018-138048.1A vulnerability has been identified in SIMATIC IT LMS (All versions), SIMATIC IT Production Suite (Versions V7.1 < V7.1 Upd3), SIMATIC IT UACVE-2018-138057.5A vulnerability has been identified in SIMATIC ET 200SP Open Controller (All versions >= V2.0 and < V2.1.6), SIMATIC S7-1500 Software ControCVE-2018-138067.8A vulnerability has been identified in SIEMENS TD Keypad Designer (All versions). A DLL hijacking vulnerability exists in all versions of SICVE-2018-138078.6A vulnerability has been identified in SCALANCE X300 (All versions < V4.0.0), SCALANCE X408 (All versions < V4.0.0), SCALANCE X414 (All versCVE-2018-138089.1A vulnerability has been identified in CP 1604 (All versions), CP 1616 (All versions). An attacker with network access to port 23/tcp could CVE-2018-138096.1A vulnerability has been identified in CP 1604 (All versions), CP 1616 (All versions). The integrated web server of the affected CP devices CVE-2018-138106.5A vulnerability has been identified in CP 1604 (All versions), CP 1616 (All versions). The integrated configuration web server of the affectCVE-2018-138115.5A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) (All Versions < V15.1). Password hashes with insufficient computational eCVE-2018-138127.5A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15 Update 4), SIMATIC HMI Comfort Outdoor PanelsCVE-2018-138138.1A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15 Update 4), SIMATIC HMI Comfort Outdoor Panels
CVE-2018-13800: High severity, CVSS 7.3 | Vulnix