CVE-2018-13801

HighCVSS 8.8/10Last modified Jun 17, 2026

Description

A vulnerability has been identified in ROX II (All versions < V2.12.1). An attacker with network access to port 22/tcp and valid low-privileged user credentials for the target device could perform a privilege escalation and gain root privileges. Successful exploitation requires user privileges of a low-privileged user but no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the system.

Metrics

CVSS 3.0 8.8/10CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Oct 10, 2018
Last modified
Jun 17, 2026
NVD status
Modified

Related CVEs from 2018

CVE-2018-138027.2A vulnerability has been identified in ROX II (All versions < V2.12.1). An authenticated attacker with a high-privileged user account accessCVE-2018-138048.1A vulnerability has been identified in SIMATIC IT LMS (All versions), SIMATIC IT Production Suite (Versions V7.1 < V7.1 Upd3), SIMATIC IT UACVE-2018-138057.5A vulnerability has been identified in SIMATIC ET 200SP Open Controller (All versions >= V2.0 and < V2.1.6), SIMATIC S7-1500 Software ControCVE-2018-138067.8A vulnerability has been identified in SIEMENS TD Keypad Designer (All versions). A DLL hijacking vulnerability exists in all versions of SICVE-2018-138078.6A vulnerability has been identified in SCALANCE X300 (All versions < V4.0.0), SCALANCE X408 (All versions < V4.0.0), SCALANCE X414 (All versCVE-2018-138089.1A vulnerability has been identified in CP 1604 (All versions), CP 1616 (All versions). An attacker with network access to port 23/tcp could CVE-2018-138096.1A vulnerability has been identified in CP 1604 (All versions), CP 1616 (All versions). The integrated web server of the affected CP devices CVE-2018-138106.5A vulnerability has been identified in CP 1604 (All versions), CP 1616 (All versions). The integrated configuration web server of the affectCVE-2018-138115.5A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) (All Versions < V15.1). Password hashes with insufficient computational eCVE-2018-138127.5A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15 Update 4), SIMATIC HMI Comfort Outdoor PanelsCVE-2018-138138.1A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15 Update 4), SIMATIC HMI Comfort Outdoor PanelsCVE-2018-138148.8A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V14), SIMATIC HMI Comfort Outdoor Panels 7" & 15"
CVE-2018-13801: High severity, CVSS 8.8 | Vulnix