CVE-2018-13802

HighCVSS 7.2/10Last modified Jun 17, 2026

Description

A vulnerability has been identified in ROX II (All versions < V2.12.1). An authenticated attacker with a high-privileged user account access via SSH could circumvent restrictions in place and execute arbitrary operating system commands. Successful exploitation requires that the attacker has network access to the SSH interface in on port 22/tcp. The attacker must be authenticated to exploit the vulnerability. The vulnerability could allow an attacker to execute arbitrary code on the device.

Metrics

CVSS 3.0 7.2/10CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Oct 10, 2018
Last modified
Jun 17, 2026
NVD status
Modified

Related CVEs from 2018

CVE-2018-138048.1A vulnerability has been identified in SIMATIC IT LMS (All versions), SIMATIC IT Production Suite (Versions V7.1 < V7.1 Upd3), SIMATIC IT UACVE-2018-138057.5A vulnerability has been identified in SIMATIC ET 200SP Open Controller (All versions >= V2.0 and < V2.1.6), SIMATIC S7-1500 Software ControCVE-2018-138067.8A vulnerability has been identified in SIEMENS TD Keypad Designer (All versions). A DLL hijacking vulnerability exists in all versions of SICVE-2018-138078.6A vulnerability has been identified in SCALANCE X300 (All versions < V4.0.0), SCALANCE X408 (All versions < V4.0.0), SCALANCE X414 (All versCVE-2018-138089.1A vulnerability has been identified in CP 1604 (All versions), CP 1616 (All versions). An attacker with network access to port 23/tcp could CVE-2018-138096.1A vulnerability has been identified in CP 1604 (All versions), CP 1616 (All versions). The integrated web server of the affected CP devices CVE-2018-138106.5A vulnerability has been identified in CP 1604 (All versions), CP 1616 (All versions). The integrated configuration web server of the affectCVE-2018-138115.5A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) (All Versions < V15.1). Password hashes with insufficient computational eCVE-2018-138127.5A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15 Update 4), SIMATIC HMI Comfort Outdoor PanelsCVE-2018-138138.1A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15 Update 4), SIMATIC HMI Comfort Outdoor PanelsCVE-2018-138148.8A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V14), SIMATIC HMI Comfort Outdoor Panels 7" & 15"CVE-2018-138157.5A vulnerability has been identified in SIMATIC S7-1200 (All versions), SIMATIC S7-1500 (All Versions < V2.6). An attacker could exhaust the
CVE-2018-13802: High severity, CVSS 7.2 | Vulnix