CVE-2018-1059

MediumCVSS 6.1/10Last modified Jun 17, 2026

Description

The DPDK vhost-user interface does not check to verify that all the requested guest physical range is mapped and contiguous when performing Guest Physical Addresses to Host Virtual Addresses translations. This may lead to a malicious guest exposing vhost-user backend process memory. All versions before 18.02.1 are vulnerable.

Metrics

CVSS 3.0 6.1/10CVSS:3.0/AV:A/AC:H/PR:N/UI:N/S:C/C:H/I:N/A:N

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Apr 24, 2018
Last modified
Jun 17, 2026
NVD status
Modified

Related CVEs from 2018

CVE-2018-105907.5In Advantech WebAccess versions V8.2_20170817 and prior, WebAccess versions V8.3.0 and prior, WebAccess Dashboard versions V.2.0.15 and prioCVE-2018-105916.1In Advantech WebAccess versions V8.2_20170817 and prior, WebAccess versions V8.3.0 and prior, WebAccess Dashboard versions V.2.0.15 and prioCVE-2018-105929.8Yokogawa STARDOM FCJ controllers R4.02 and prior, FCN-100 controllers R4.02 and prior, FCN-RTU controllers R4.02 and prior, and FCN-500 contCVE-2018-105935.6A vulnerability in DB Manager version 3.0.1.0 and previous and PerformA version 3.0.0.0 and previous allows an authorized user with access tCVE-2018-105949.8Delta Industrial Automation COMMGR from Delta Electronics versions 1.08 and prior with accompanying PLC Simulators (DVPSimulator EH2, EH3, ECVE-2018-105956.3A vulnerability in ReadA version 1.1.0.2 and previous allows an authorized user with access to a privileged account on a BD Kiestra system (CVE-2018-105967.1Medtronic 2090 CareLink Programmer uses a virtual private network connection to securely download updates. It does not verify it is still CVE-2018-105978.3IntelliVue Patient Monitors MP Series (including MP2/X2/MP30/MP50/MP70/NP90/MX700/800) Rev B-M, IntelliVue Patient Monitors MX (MX400-550) RCVE-2018-105988.1CNCSoft Version 1.00.83 and prior with ScreenEditor Version 1.00.54 has two out-of-bounds read vulnerabilities could cause the software to cCVE-2018-105995.3IntelliVue Patient Monitors MP Series (including MP2/X2/MP30/MP50/MP70/NP90/MX700/800) Rev B-M, IntelliVue Patient Monitors MX (MX400-550) RCVE-2018-10607.5python before versions 2.7.15, 3.4.9, 3.5.6rc1, 3.6.5rc1 and 3.7.0 is vulnerable to catastrophic backtracking in pop3lib's apop() method. AnCVE-2018-106009.8SEL AcSELerator Architect version 2.2.24.0 and prior allows unsanitized input to be passed to the XML parser, which may allow disclosure and
CVE-2018-1059: Medium severity, CVSS 6.1 | Vulnix