CVE-2018-10594

CriticalCVSS 9.8/10Last modified Jun 17, 2026

Description

Delta Industrial Automation COMMGR from Delta Electronics versions 1.08 and prior with accompanying PLC Simulators (DVPSimulator EH2, EH3, ES2, SE, SS2 and AHSIM_5x0, AHSIM_5x1) utilize a fixed-length stack buffer where an unverified length value can be read from the network packets via a specific network port, causing the buffer to be overwritten. This may allow remote code execution, cause the application to crash, or result in a denial-of-service condition in the application server.

Metrics

CVSS 3.0 9.8/10CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Jun 26, 2018
Last modified
Jun 17, 2026
NVD status
Modified

Related CVEs from 2018

CVE-2018-105956.3A vulnerability in ReadA version 1.1.0.2 and previous allows an authorized user with access to a privileged account on a BD Kiestra system (CVE-2018-105967.1Medtronic 2090 CareLink Programmer uses a virtual private network connection to securely download updates. It does not verify it is still CVE-2018-105978.3IntelliVue Patient Monitors MP Series (including MP2/X2/MP30/MP50/MP70/NP90/MX700/800) Rev B-M, IntelliVue Patient Monitors MX (MX400-550) RCVE-2018-105988.1CNCSoft Version 1.00.83 and prior with ScreenEditor Version 1.00.54 has two out-of-bounds read vulnerabilities could cause the software to cCVE-2018-105995.3IntelliVue Patient Monitors MP Series (including MP2/X2/MP30/MP50/MP70/NP90/MX700/800) Rev B-M, IntelliVue Patient Monitors MX (MX400-550) RCVE-2018-10607.5python before versions 2.7.15, 3.4.9, 3.5.6rc1, 3.6.5rc1 and 3.7.0 is vulnerable to catastrophic backtracking in pop3lib's apop() method. AnCVE-2018-106009.8SEL AcSELerator Architect version 2.2.24.0 and prior allows unsanitized input to be passed to the XML parser, which may allow disclosure andCVE-2018-106018.2IntelliVue Patient Monitors MP Series (including MP2/X2/MP30/MP50/MP70/NP90/MX700/800) Rev B-M, IntelliVue Patient Monitors MX (MX400-550) RCVE-2018-106028.8WECON LeviStudio Versions 1.8.29 and 1.8.44 have multiple stack-based buffer overflow vulnerabilities that can be exploited when the applicaCVE-2018-106039.8Martem TELEM GW6 and GWM devices with firmware 2018.04.18-linux_4-01-601cb47 and prior do not perform authentication of IEC-104 control commCVE-2018-106048.8SEL Compass version 3.0.5.1 and prior allows all users full access to the SEL Compass directory, which may allow modification or overwritingCVE-2018-106058.8Martem TELEM GW6/GWM versions prior to 2.0.87-4018403-k4 may allow unprivileged users to modify/upload a new system configuration or take th
CVE-2018-10594: Critical severity, CVSS 9.8 | Vulnix