CVE-2018-10596

HighCVSS 7.1/10Last modified Jun 17, 2026

Description

Medtronic 2090 CareLink Programmer

uses a virtual private network connection to securely download updates. It does not verify it is still connected to this virtual private network before downloading updates. The affected products initially establish an encapsulated IP-based VPN connection to a Medtronic-hosted update network. Once the VPN is established, it makes a request to a HTTP (non-TLS) server across the VPN for updates, which responds and provides any available updates. The programmer-side (client) service responsible for this HTTP request does not check to ensure it is still connected to the VPN before making the HTTP request. Thus, an attacker could cause the VPN connection to terminate (through various methods and attack points) and intercept the HTTP request, responding with malicious updates via a man-in-the-middle attack. The affected products do not verify the origin or integrity of these updates, as it insufficiently relied on the security of the VPN. An attacker with remote network access to the programmer could influence these communications.

Metrics

CVSS 3.1 7.1/10CVSS:3.1/AV:N/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:H

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Jul 3, 2018
Last modified
Jun 17, 2026
NVD status
Modified

Related CVEs from 2018

CVE-2018-105978.3IntelliVue Patient Monitors MP Series (including MP2/X2/MP30/MP50/MP70/NP90/MX700/800) Rev B-M, IntelliVue Patient Monitors MX (MX400-550) RCVE-2018-105988.1CNCSoft Version 1.00.83 and prior with ScreenEditor Version 1.00.54 has two out-of-bounds read vulnerabilities could cause the software to cCVE-2018-105995.3IntelliVue Patient Monitors MP Series (including MP2/X2/MP30/MP50/MP70/NP90/MX700/800) Rev B-M, IntelliVue Patient Monitors MX (MX400-550) RCVE-2018-10607.5python before versions 2.7.15, 3.4.9, 3.5.6rc1, 3.6.5rc1 and 3.7.0 is vulnerable to catastrophic backtracking in pop3lib's apop() method. AnCVE-2018-106009.8SEL AcSELerator Architect version 2.2.24.0 and prior allows unsanitized input to be passed to the XML parser, which may allow disclosure andCVE-2018-106018.2IntelliVue Patient Monitors MP Series (including MP2/X2/MP30/MP50/MP70/NP90/MX700/800) Rev B-M, IntelliVue Patient Monitors MX (MX400-550) RCVE-2018-106028.8WECON LeviStudio Versions 1.8.29 and 1.8.44 have multiple stack-based buffer overflow vulnerabilities that can be exploited when the applicaCVE-2018-106039.8Martem TELEM GW6 and GWM devices with firmware 2018.04.18-linux_4-01-601cb47 and prior do not perform authentication of IEC-104 control commCVE-2018-106048.8SEL Compass version 3.0.5.1 and prior allows all users full access to the SEL Compass directory, which may allow modification or overwritingCVE-2018-106058.8Martem TELEM GW6/GWM versions prior to 2.0.87-4018403-k4 may allow unprivileged users to modify/upload a new system configuration or take thCVE-2018-106068.8WECON LeviStudio Versions 1.8.29 and 1.8.44 have multiple heap-based buffer overflow vulnerabilities that can be exploited when the applicatCVE-2018-106077.5Martem TELEM GW6 and GWM devices with firmware 2018.04.18-linux_4-01-601cb47 and prior allow the creation of new connections to one or more
CVE-2018-10596: High severity, CVSS 7.1 | Vulnix