CVE-2026-71915

HighCVSS 7.2/10Last modified Oct 13, 2026

Description

Multiple DrayTek VigorSwitch models contain a command injection vulnerability in the jsonstatus function. The vulnerability is caused by insufficient filtering of the usescript, usefile, and option fields before command execution. A remote attacker can trigger this vulnerability via crafted input to execute arbitrary commands with root privileges. Exploitation requires valid administrative credentials for the device's web management interface.

Metrics

CVSS 3.1 7.2/10CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Aug 24, 2026
Last modified
Oct 13, 2026
NVD status
Deferred

Related CVEs from 2026

CVE-2026-719167.2Multiple DrayTek VigorSwitch models contain a command injection vulnerability in the commandTable function. The vulnerability is caused by iCVE-2026-719177.2Multiple DrayTek VigorSwitch models contain a command injection vulnerability in the pingtrace function. The vulnerability is caused by insuCVE-2026-719187.2Multiple DrayTek VigorSwitch models contain a command injection vulnerability in the webBackupAction function. The vulnerability is caused bCVE-2026-719197.2Multiple DrayTek VigorSwitch models contain a command injection vulnerability in the sysreboot function. The vulnerability is caused by insuCVE-2026-71929.3A stack-based buffer overflow vulnerability in the Dbit T-CPE301K 4G WiFi minirouter allows an authenticated attacker to cause a denial of sCVE-2026-719204.9Multiple DrayTek VigorSwitch models contain a null pointer dereference vulnerability in the formlogout function. The vulnerability is causedCVE-2026-719219.8Multiple DrayTek VigorSwitch models contain a pre-authentication command injection vulnerability in the setget.cgi interface. The vulnerabilCVE-2026-719227.5Multiple DrayTek VigorSwitch models contain a pre-authentication null pointer dereference vulnerability in the setget.cgi interface. The vulCVE-2026-719237.2Multiple DrayTek VigorSwitch models contain a command injection vulnerability in the auth_set function. The vulnerability is caused by insufCVE-2026-719247.2Multiple DrayTek VigorSwitch models contain a command injection vulnerability in the getVid function. The vulnerability is caused by insuffiCVE-2026-719257.2Multiple DrayTek VigorSwitch models contain a command injection vulnerability in the getDetail function. The vulnerability is caused by insuCVE-2026-719267.2Multiple DrayTek VigorSwitch models contain a command injection vulnerability in the setDevice function. The vulnerability is caused by insu
CVE-2026-71915: High severity, CVSS 7.2 | Vulnix