CVE-2026-71919

HighCVSS 7.2/10Last modified Oct 13, 2026

Description

Multiple DrayTek VigorSwitch models contain a command injection vulnerability in the sysreboot function. The vulnerability is caused by insufficient filtering of the config, act, pathN, and valueN fields before command execution. A remote attacker can trigger this vulnerability via crafted input to execute arbitrary commands with root privileges. Exploitation requires valid administrative credentials for the device's web management interface.

Metrics

CVSS 3.1 7.2/10CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H

Weakness enumeration

Affected software

VendorProductVersions
DrayTek CorporationVigorSwitch G2540xs< 3.9.10
DrayTek CorporationVigorSwitch P2540xs< 3.9.10
DrayTek CorporationVigorSwitch FX2120< 3.9.10
DrayTek CorporationVigorSwitch G2282x< 2.10.6
DrayTek CorporationVigorSwitch P2282x< 2.10.6
DrayTek CorporationVigorSwitch Q2300x< 2.10.7
DrayTek CorporationVigorSwitch PQ2300xb< 2.10.7
DrayTek CorporationVigorSwitch G2542x< 3.10.6
DrayTek CorporationVigorSwitch P2542x< 3.10.6
DrayTek CorporationVigorSwitch P2542xh< 3.10.6
DrayTek CorporationVigorSwitch PX2060< 2.9.10
DrayTek CorporationVigorSwitch G1280< 2.9.10
DrayTek CorporationVigorSwitch P1280< 2.9.10
DrayTek CorporationVigorSwitch P1281x< 2.9.10
DrayTek CorporationVigorSwitch G1282< 2.9.10
DrayTek CorporationVigorSwitch P1282< 2.9.10
DrayTek CorporationVigorSwitch G2121< 2.9.10
DrayTek CorporationVigorSwitch P2121< 2.9.10
DrayTek CorporationVigorSwitch PQ2121x< 2.9.10
DrayTek CorporationVigorSwitch Q2121x< 2.9.10
DrayTek CorporationVigorSwitch G2280x< 2.9.10
DrayTek CorporationVigorSwitch P2280x< 2.9.10
DrayTek CorporationVigorSwitch Q2200x< 2.9.10
DrayTek CorporationVigorSwitch PQ2200xb< 2.9.10
DrayTek CorporationVigorSwitch G2100< 2.9.10
DrayTek CorporationVigorSwitch P2100< 2.9.10
DrayTek CorporationVigorSwitch G2540x< 2.9.10
DrayTek CorporationVigorSwitch P2540x< 2.9.10

References

Timeline

Published
Aug 24, 2026
Last modified
Oct 13, 2026
NVD status
Deferred

Related CVEs from 2026

CVE-2026-71929.3A stack-based buffer overflow vulnerability in the Dbit T-CPE301K 4G WiFi minirouter allows an authenticated attacker to cause a denial of sCVE-2026-719204.9Multiple DrayTek VigorSwitch models contain a null pointer dereference vulnerability in the formlogout function. The vulnerability is causedCVE-2026-719219.8Multiple DrayTek VigorSwitch models contain a pre-authentication command injection vulnerability in the setget.cgi interface. The vulnerabilCVE-2026-719227.5Multiple DrayTek VigorSwitch models contain a pre-authentication null pointer dereference vulnerability in the setget.cgi interface. The vulCVE-2026-719237.2Multiple DrayTek VigorSwitch models contain a command injection vulnerability in the auth_set function. The vulnerability is caused by insufCVE-2026-719247.2Multiple DrayTek VigorSwitch models contain a command injection vulnerability in the getVid function. The vulnerability is caused by insuffiCVE-2026-719257.2Multiple DrayTek VigorSwitch models contain a command injection vulnerability in the getDetail function. The vulnerability is caused by insuCVE-2026-719267.2Multiple DrayTek VigorSwitch models contain a command injection vulnerability in the setDevice function. The vulnerability is caused by insuCVE-2026-719277.2Multiple DrayTek VigorSwitch models contain a command injection vulnerability in the rebDevice function. The vulnerability is caused by insuCVE-2026-719287.2Multiple DrayTek VigorSwitch models contain a command injection vulnerability in the fdftDevice function. The vulnerability is caused by insCVE-2026-719297.2Multiple DrayTek VigorSwitch models contain a command injection vulnerability in the setDevProto function. The vulnerability is caused by inCVE-2026-71938.6A vulnerability relating to the use of predefined credentials in the Dbit T-CPE301K 4G WiFi mini-router allows an attacker connected to the