CVE-2024-43658

HighCVSS 7.2/10Last modified Jun 17, 2026

Description

Patch traversal, External Control of File Name or Path vulnerability in Iocharger Home allows deletion of arbitrary files This issue affects Iocharger firmware for AC model before firmware version 25010801.

Likelihood: High, but requires authentication

Impact: Critical – The vulnerability can be used to delete any file on the charging station, severely impacting the integrity of the charging station. Furthermore, the vulnerability could be used to delete binaries required for the functioning of the charging station, severely impacting the availability of the charging station.

CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads compromised of the integrity and availability of the device (VVC:N/VI:H/VA:H), with no effect on subsequent systems (SC:N/SI:N/SA:N). We do not forsee a safety impact (S:N). This attack can be automated (AU:Y).

Metrics

CVSS 4.0 7.2/10CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:N/AU:Y/R:X/V:X/RE:X/U:X

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Jan 9, 2025
Last modified
Jun 17, 2026
NVD status
Deferred

Related CVEs from 2024

CVE-2024-436597.2After gaining access to the firmware of a charging station, a file at <redacted> can be accessed to obtain default credentials that are the CVE-2024-43665.4The Spectra – WordPress Gutenberg Blocks plugin for WordPress is vulnerable to Stored Cross-Site Scripting via the ‘block_id’ parameter in vCVE-2024-436607.5The CGI script <redacted>.sh can be used to download any file on the filesystem. This issue affects Iocharger firmware for AC model chargerCVE-2024-436619.8The <redacted>.so library, which is used by <redacted>, is vulnerable to a buffer overflow in the code that handles the deletion of certificCVE-2024-436625.3The <redacted>.exe or <redacted>.exe CGI binary can be used to upload arbitrary files to /tmp/upload/ or /tmp/ respectively as any user, altCVE-2024-436639.8There are many buffer overflow vulnerabilities present in several CGI binaries of the charging station.This issue affects Iocharger firmwareCVE-2024-43678.8A type check was missing when handling fonts in PDF.js, which would allow arbitrary JavaScript execution in the PDF.js context. This vulneraCVE-2024-43688.8Use after free in Dawn in Google Chrome prior to 124.0.6367.118 allowed a remote attacker to potentially exploit heap corruption via a craftCVE-2024-436836.1URL Redirection to Untrusted Site ('Open Redirect') vulnerability in Microchip TimeProvider 4100 allows XSS Through HTTP Headers.This issue CVE-2024-436848.8Cross-Site Request Forgery (CSRF) vulnerability in Microchip TimeProvider 4100 allows Cross Site Request Forgery, Cross-Site Scripting (XSS)CVE-2024-436859.8Improper Authentication vulnerability in Microchip TimeProvider 4100 (login modules) allows Session Hijacking.This issue affects TimeProvideCVE-2024-436866.1Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting') vulnerability in Microchip TimeProvider 4100 (da
CVE-2024-43658: High severity, CVSS 7.2 | Vulnix