CVE-2024-43662

MediumCVSS 5.3/10Last modified Jun 17, 2026

Description

The <redacted>.exe or <redacted>.exe CGI binary can be used to upload arbitrary files to /tmp/upload/ or /tmp/ respectively as any user, although the user interface for uploading files is only shown to the iocadmin user.

This issue affects Iocharger firmware for AC models before version 24120701.

Likelihood: Moderate – An attacker will need to have knowledge of this CGI binary, e.g. by finding it in firmware. Furthermore, the attacker will need a (low privilege) account to gain access to the <redacted>.exe or <redacted>.exe CGI binary and upload the file, or convince a user with such access to upload it.

Impact: Low – The attacker can upload arbitrary files to /tmp/upload/ or /tmp/. However, the attacker is unable to access or use these files without other vulnerabilities.

CVSS clarification. The attack can be executed over any network connection the station is listening to and serves the web interface (AV:N), and there are no additional security measure sin place that need to be circumvented (AC:L), the attack does not rely on preconditions (AT:N). The attack does require authentication, but the level of authentication is irrelevant (PR:L), it does not require user interaction (UI:N). Artitrary files can be uploaded, be these files will not be in a location where they can influence confidentiality or availability and have a minimal impact on device integrity (VC:N/VI:L/VA:N). There is no impact on subsequent systems. (SC:N/SI:N/SA:N). While this device is an EV charger handing significant amounts of power, we do not expect this vulnerability to have a safety impact. The attack can be automated (AU:Y).

Metrics

CVSS 4.0 5.3/10CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:Y/R:X/V:X/RE:X/U:X

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Jan 9, 2025
Last modified
Jun 17, 2026
NVD status
Deferred

Related CVEs from 2024

CVE-2024-436639.8There are many buffer overflow vulnerabilities present in several CGI binaries of the charging station.This issue affects Iocharger firmwareCVE-2024-43678.8A type check was missing when handling fonts in PDF.js, which would allow arbitrary JavaScript execution in the PDF.js context. This vulneraCVE-2024-43688.8Use after free in Dawn in Google Chrome prior to 124.0.6367.118 allowed a remote attacker to potentially exploit heap corruption via a craftCVE-2024-436836.1URL Redirection to Untrusted Site ('Open Redirect') vulnerability in Microchip TimeProvider 4100 allows XSS Through HTTP Headers.This issue CVE-2024-436848.8Cross-Site Request Forgery (CSRF) vulnerability in Microchip TimeProvider 4100 allows Cross Site Request Forgery, Cross-Site Scripting (XSS)CVE-2024-436859.8Improper Authentication vulnerability in Microchip TimeProvider 4100 (login modules) allows Session Hijacking.This issue affects TimeProvideCVE-2024-436866.1Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting') vulnerability in Microchip TimeProvider 4100 (daCVE-2024-436876.1Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting') vulnerability in Microchip TimeProvider 4100 (baCVE-2024-436887.3cron/entry.c in vixie cron before 9cc8ab1, as used in OpenBSD 7.4 and 7.5, allows a heap-based buffer underflow and memory corruption. NOTE:CVE-2024-436899.8Stack-based buffer overflow vulnerability exists in ELECOM wireless access points. By processing a specially crafted HTTP request, arbitraryCVE-2024-43696.8An information disclosure flaw was found in OpenShift's internal image registry operator. The AZURE_CLIENT_SECRET can be exposed through an CVE-2024-436908.0Inclusion of Functionality from Untrusted Control Sphere(CWE-829) in the Command Centre Server and Workstations may allow an attacker to per