CVE-2024-2594

MediumCVSS 6.1/10Last modified Jun 17, 2026

Description

Vulnerability in AMSS++ version 4.31, which does not sufficiently encode user-controlled input, resulting in a Cross-Site Scripting (XSS) vulnerability through /amssplus/admin/index.php, in multiple parameters. This vulnerability could allow a remote attacker to send a specially crafted URL to an authenticated user and steal their session cookie credentials.

Metrics

CVSS 3.1 6.1/10CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Mar 18, 2024
Last modified
Jun 17, 2026
NVD status
Analyzed

Related CVEs from 2024

CVE-2024-259406.3`bhyveload -h <host-path>` may be used to grant loader access to the <host-path> directory tree on the host. Affected versions of bhyveloadCVE-2024-259413.3The jail(2) system call has not limited a visiblity of allocated TTYs (the kern.ttys sysctl). This gives rise to an information leak about CVE-2024-259426.8Dell PowerEdge Server BIOS contains an Improper SMM communication buffer verification vulnerability. A physical high privileged attacker couCVE-2024-259439.8iDRAC9, versions prior to 7.00.00.172 for 14th Generation and 7.10.50.00 for 15th and 16th Generations, contains a session hijacking vulneraCVE-2024-259447.5Dell OpenManage Enterprise, v4.0 and prior, contain(s) a path traversal vulnerability. An unauthenticated remote attacker could potentially CVE-2024-259468.8Dell vApp Manager, versions prior to 9.2.4.9 contain a Command Injection Vulnerability. An authorized attacker could potentially exploit thiCVE-2024-259474.4Dell iDRAC Service Module version 5.3.0.0 and prior, contain an Out of bound Read Vulnerability. A privileged local attacker could execute aCVE-2024-259484.4Dell iDRAC Service Module version 5.3.0.0 and prior, contain a Out of bound Write Vulnerability. A privileged local attacker could execute aCVE-2024-259498.8Dell OS10 Networking Switches, versions10.5.6.x, 10.5.5.x, 10.5.4.x and 10.5.3.x ,contain an improper authorization vulnerability. A remote CVE-2024-25956.1Vulnerability in AMSS++ version 4.31, which does not sufficiently encode user-controlled input, resulting in a Cross-Site Scripting (XSS) vuCVE-2024-259518.0A command injection vulnerability exists in local RACADM. A malicious authenticated user could gain control of the underlying operating systCVE-2024-259526.0Dell PowerScale OneFS versions 8.2.2.x through 9.7.0.x contains an UNIX symbolic link (symlink) following vulnerability. A local high privil
CVE-2024-2594: Medium severity, CVSS 6.1 | Vulnix