CVE-2024-25949

HighCVSS 8.8/10Last modified Jun 17, 2026

Description

Dell OS10 Networking Switches, versions10.5.6.x, 10.5.5.x, 10.5.4.x and 10.5.3.x ,contain an improper authorization vulnerability. A remote authenticated attacker could potentially exploit this vulnerability leading to escalation of privileges.

Metrics

CVSS 3.1 8.8/10CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Jun 12, 2024
Last modified
Jun 17, 2026
NVD status
Modified

Related CVEs from 2024

CVE-2024-25956.1Vulnerability in AMSS++ version 4.31, which does not sufficiently encode user-controlled input, resulting in a Cross-Site Scripting (XSS) vuCVE-2024-259518.0A command injection vulnerability exists in local RACADM. A malicious authenticated user could gain control of the underlying operating systCVE-2024-259526.0Dell PowerScale OneFS versions 8.2.2.x through 9.7.0.x contains an UNIX symbolic link (symlink) following vulnerability. A local high privilCVE-2024-259536.0Dell PowerScale OneFS versions 9.4.0.x through 9.7.0.x contains an UNIX symbolic link (symlink) following vulnerability. A local high privilCVE-2024-259547.5Dell PowerScale OneFS, versions 9.5.0.x through 9.7.0.x, contain an insufficient session expiration vulnerability. A remote unauthenticated CVE-2024-259558.8Dell vApp Manager, versions prior to 9.2.4.9 contain a Command Injection Vulnerability. An authorized attacker could potentially exploit thiCVE-2024-259565.5Dell Grab for Windows, versions 5.0.4 and below, contains an improper file permissions vulnerability. A locally authenticated attacker couldCVE-2024-259575.5Dell Grab for Windows, versions 5.0.4 and below, contains a cleartext storage of sensitive information vulnerability in its appsync module. CVE-2024-259587.8Dell Grab for Windows, versions up to and including 5.0.4, contain Weak Application Folder Permissions vulnerability. A local authenticated CVE-2024-259595.5Dell PowerScale OneFS versions 9.4.0.x through 9.7.0.x contains an insertion of sensitive information into log file vulnerability. A low priCVE-2024-25966.1Vulnerability in AMSS++ version 4.31, which does not sufficiently encode user-controlled input, resulting in a Cross-Site Scripting (XSS) vuCVE-2024-259607.8Dell PowerScale OneFS versions 8.2.2.x through 9.7.0.x contains a cleartext transmission of sensitive information vulnerability. A local low
CVE-2024-25949: High severity, CVSS 8.8 | Vulnix