CVE-2022-30310

CriticalCVSS 9.8/10Last modified Jun 17, 2026

Description

In Festo Controller CECC-X-M1 product family in multiple versions, the http-endpoint "cecc-x-acknerr-request" POST request doesn’t check for port syntax. This can result in unauthorized execution of system commands with root privileges due to improper access control command injection.

Metrics

CVSS 3.1 9.8/10CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Jun 13, 2022
Last modified
Jun 17, 2026
NVD status
Modified

Related CVEs from 2022

CVE-2022-303119.8In Festo Controller CECC-X-M1 product family in multiple versions, the http-endpoint "cecc-x-refresh-request" POST request doesn’t check forCVE-2022-303126.5The Trend Controls IC protocol through 2022-05-06 allows Cleartext Transmission of Sensitive Information. According to FSCT-2022-0050, thereCVE-2022-303137.5Honeywell Experion PKS Safety Manager through 2022-05-06 has Missing Authentication for a Critical Function. According to FSCT-2022-0051, thCVE-2022-303144.6Honeywell Experion PKS Safety Manager 5.02 uses Hard-coded Credentials. According to FSCT-2022-0052, there is a Honeywell Experion PKS SafetCVE-2022-303159.8Honeywell Experion PKS Safety Manager (SM and FSC) through 2022-05-06 has Insufficient Verification of Data Authenticity. According to FSCT-CVE-2022-303166.8Honeywell Experion PKS Safety Manager 5.02 has Insufficient Verification of Data Authenticity. According to FSCT-2022-0054, there is a HoneyCVE-2022-303179.1Honeywell Experion LX through 2022-05-06 has Missing Authentication for a Critical Function. According to FSCT-2022-0055, there is a HoneyweCVE-2022-303189.8Honeywell ControlEdge through R151.1 uses Hard-coded Credentials. According to FSCT-2022-0056, there is a Honeywell ControlEdge hardcoded crCVE-2022-303198.1Saia Burgess Controls (SBC) PCD through 2022-05-06 allows Authentication bypass. According to FSCT-2022-0062, there is a Saia Burgess ControCVE-2022-30326.5When receiving an HTML email that contained an <code>iframe</code> element, which used a <code>srcdoc</code> attribute to define the inner HCVE-2022-303204.3Saia Burgess Controls (SBC) PCD through 2022-05-06 uses a Broken or Risky Cryptographic Algorithm. According to FSCT-2022-0063, there is a SCVE-2022-303218.6go-getter up to 1.5.11 and 2.0.2 allowed arbitrary host access via go-getter path traversal, symlink processing, and command injection flaws
CVE-2022-30310: Critical severity, CVSS 9.8 | Vulnix