CVE-2022-30316

MediumCVSS 6.8/10Last modified Jun 17, 2026

Description

Honeywell Experion PKS Safety Manager 5.02 has Insufficient Verification of Data Authenticity. According to FSCT-2022-0054, there is a Honeywell Experion PKS Safety Manager unauthenticated firmware update issue. The affected components are characterized as: Firmware update functionality. The potential impact is: Firmware manipulation. The Honeywell Experion PKS Safety Manager utilizes the DCOM-232/485 communication FTA serial interface and Enea POLO bootloader for firmware management purposes. An engineering workstation running the Safety Builder software communicates via serial or serial-over-ethernet link with the DCOM-232/485 interface. Firmware images were found to have no authentication (in the form of firmware signing) and only relied on insecure checksums for regular integrity checks. Firmware images are unsigned. An attacker with access to the serial interface (either through physical access, a compromised EWS or an exposed serial-to-ethernet gateway) can utilize hardcoded credentials (see FSCT-2022-0052) for the POLO bootloader to control the boot process and push malicious firmware images to the controller allowing for firmware manipulation, remote code execution and denial of service impacts. A mitigating factor is that in order for a firmware update to be initiated, the Safety Manager has to be rebooted which is typically done by means of physical controls on the Safety Manager itself. As such, an attacker would have to either lay dormant until a legitimate reboot occurs or possibly attempt to force a reboot through a secondary vulnerability.

Metrics

CVSS 3.1 6.8/10CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Jul 28, 2022
Last modified
Jun 17, 2026
NVD status
Modified

Related CVEs from 2022

CVE-2022-303179.1Honeywell Experion LX through 2022-05-06 has Missing Authentication for a Critical Function. According to FSCT-2022-0055, there is a HoneyweCVE-2022-303189.8Honeywell ControlEdge through R151.1 uses Hard-coded Credentials. According to FSCT-2022-0056, there is a Honeywell ControlEdge hardcoded crCVE-2022-303198.1Saia Burgess Controls (SBC) PCD through 2022-05-06 allows Authentication bypass. According to FSCT-2022-0062, there is a Saia Burgess ControCVE-2022-30326.5When receiving an HTML email that contained an <code>iframe</code> element, which used a <code>srcdoc</code> attribute to define the inner HCVE-2022-303204.3Saia Burgess Controls (SBC) PCD through 2022-05-06 uses a Broken or Risky Cryptographic Algorithm. According to FSCT-2022-0063, there is a SCVE-2022-303218.6go-getter up to 1.5.11 and 2.0.2 allowed arbitrary host access via go-getter path traversal, symlink processing, and command injection flawsCVE-2022-303228.6go-getter up to 1.5.11 and 2.0.2 allowed asymmetric resource exhaustion when go-getter processed malicious HTTP responses. Fixed in 1.6.1 anCVE-2022-303238.6go-getter up to 1.5.11 and 2.0.2 panicked when processing password-protected ZIP files. Fixed in 1.6.1 and 2.1.0.CVE-2022-303249.8HashiCorp Nomad and Nomad Enterprise version 0.2.0 up to 1.3.0 were impacted by go-getter vulnerabilities enabling privilege escalation throCVE-2022-303258.8An issue was found on TRENDnet TEW-831DR 1.0 601.130.1.1356 devices. The default pre-shared key for the Wi-Fi networks is the same for everyCVE-2022-303265.4An issue was found on TRENDnet TEW-831DR 1.0 601.130.1.1356 devices. The network pre-shared key field on the web interface is vulnerable to CVE-2022-303276.5An issue was found on TRENDnet TEW-831DR 1.0 601.130.1.1356 devices. The web interface is vulnerable to CSRF. An attacker can change the pre
CVE-2022-30316: Medium severity, CVSS 6.8 | Vulnix