Description

PSI GridConnect GmbH Telecontrol Gateway and Smart Telecontrol Unit family, IEC104 Security Proxy versions Telecontrol Gateway 3G Versions 4.2.21, 5.0.27, 5.1.19, 6.0.16 and prior, and Telecontrol Gateway XS-MU Versions 4.2.21, 5.0.27, 5.1.19, 6.0.16 and prior, and Telecontrol Gateway VM Versions 4.2.21, 5.0.27, 5.1.19, 6.0.16 and prior, and Smart Telecontrol Unit TCG Versions 5.0.27, 5.1.19, 6.0.16 and prior, and IEC104 Security Proxy Version 2.2.10 and prior The web application browser interprets input as active HTML, JavaScript, or VBScript, which could allow an attacker to execute arbitrary code.

Metrics

CVSS 3.1 8.8/10CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Mar 5, 2019
Last modified
Jun 17, 2026
NVD status
Modified

Related CVEs from 2019

CVE-2019-65294.9An attacker could specially craft an FTP request that could crash the PR100088 Modbus gateway versions prior to release R02 (or Software VerCVE-2019-65307.8Panasonic FPWIN Pro version 7.3.0.0 and prior allows attacker-created project files to be loaded by an authenticated user causing heap-basedCVE-2019-65318.1An attacker could retrieve passwords from a HTTP GET request from the Kunbus PR100088 Modbus gateway versions prior to Release R02 (or SoftwCVE-2019-65327.8Panasonic FPWIN Pro version 7.3.0.0 and prior allows attacker-created project files to be loaded by an authenticated user triggering incompaCVE-2019-65339.1Registers used to store Modbus values can be read and written from the web interface without authentication in the PR100088 Modbus gateway vCVE-2019-65347.8The uncontrolled search path element vulnerability in Gemalto Sentinel UltraPro Client Library ux32w.dll Versions 1.3.0, 1.3.1, and 1.3.2 enCVE-2019-65357.5Mitsubishi Electric Q03/04/06/13/26UDVCPU: serial number 20081 and prior, Q04/06/13/26UDPVCPU: serial number 20081 and prior, and Q03UDECPU,CVE-2019-65367.8Opening a specially crafted LCDS LAquis SCADA before 4.3.1.71 ELS file may result in a write past the end of an allocated buffer, which may CVE-2019-65377.8Multiple stack-based buffer overflow vulnerabilities in WECON LeviStudioU version 1.8.56 and prior may be exploited when parsing strings witCVE-2019-65386.5The Conexus telemetry protocol utilized within Medtronic MyCareLink Monitor versions 24950 and 24952, CareLink Monitor version 2490C, CareLiCVE-2019-65397.8Several heap-based buffer overflow vulnerabilities in WECON LeviStudioU version 1.8.56 and prior have been identified, which may allow arbitCVE-2019-65406.5The Conexus telemetry protocol utilized within Medtronic MyCareLink Monitor versions 24950 and 24952, CareLink Monitor version 2490C, CareLi
CVE-2019-6528: High severity, CVSS 8.8 | Vulnix