CVE-2019-6538

MediumCVSS 6.5/10Last modified Jun 17, 2026

Description

The Conexus telemetry protocol utilized within Medtronic MyCareLink Monitor versions 24950 and 24952, CareLink Monitor version 2490C, CareLink 2090 Programmer, Amplia CRT-D, Claria CRT-D, Compia CRT-D, Concerto CRT-D, Concerto II CRT-D, Consulta CRT-D, Evera ICD, Maximo II CRT-D and ICD, Mirro ICD, Nayamed ND ICD, Primo ICD, Protecta ICD and CRT-D, Secura ICD, Virtuoso ICD, Virtuoso II ICD, Visia AF ICD, and Viva CRT-D does not implement authentication or authorization. An attacker with adjacent short-range access to an affected product, in situations where the product’s radio is turned on, can inject, replay, modify, and/or intercept data within the telemetry communication. This communication protocol provides the ability to read and write memory values to affected implanted cardiac devices; therefore, an attacker could exploit this communication protocol to change memory in the implanted cardiac device.

Metrics

CVSS 3.1 6.5/10CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Mar 25, 2019
Last modified
Jun 17, 2026
NVD status
Modified

Related CVEs from 2019

CVE-2019-65397.8Several heap-based buffer overflow vulnerabilities in WECON LeviStudioU version 1.8.56 and prior have been identified, which may allow arbitCVE-2019-65406.5The Conexus telemetry protocol utilized within Medtronic MyCareLink Monitor versions 24950 and 24952, CareLink Monitor version 2490C, CareLiCVE-2019-65417.8A memory corruption vulnerability has been identified in WECON LeviStudioU version 1.8.56 and prior, which may allow arbitrary code executioCVE-2019-65427.5ENTTEC Datagate MK2, Storm 24, Pixelator all firmware versions prior to (70044,70050,70060)_update_05032019-482 allows an unauthenticated usCVE-2019-65439.8AVEVA Software, LLC InduSoft Web Studio prior to Version 8.1 SP3 and InTouch Edge HMI (formerly InTouch Machine Edition) prior to Version 20CVE-2019-65445.6GE Communicator, all versions prior to 4.0.517, has a service running with system privileges that may allow an unprivileged user to perform CVE-2019-65457.5AVEVA Software, LLC InduSoft Web Studio prior to Version 8.1 SP3 and InTouch Edge HMI (formerly InTouch Machine Edition) prior to Version 20CVE-2019-65467.8GE Communicator, all versions prior to 4.0.517, allows an attacker to place malicious files within the working directory of the program, whiCVE-2019-65475.5Delta Industrial Automation CNCSoft, CNCSoft ScreenEditor Version 1.00.84 and prior. An out-of-bounds read vulnerability may cause the softwCVE-2019-65489.8GE Communicator, all versions prior to 4.0.517, contains two backdoor accounts with hardcoded credentials, which may allow control over the CVE-2019-65497.2An attacker could retrieve plain-text credentials stored in a XML file on PR100088 Modbus gateway versions prior to Release R02 (or SoftwareCVE-2019-65509.8Advantech WebAccess/SCADA, Versions 8.3.5 and prior. Multiple stack-based buffer overflow vulnerabilities, caused by a lack of proper valida
CVE-2019-6538: Medium severity, CVSS 6.5 | Vulnix