CVE-2018-7225

CriticalCVSS 9.8/10Last modified Jun 17, 2026

Description

An issue was discovered in LibVNCServer through 0.9.11. rfbProcessClientNormalMessage() in rfbserver.c does not sanitize msg.cct.length, leading to access to uninitialized and potentially sensitive data or possibly unspecified other impact (e.g., an integer overflow) via specially crafted VNC packets.

Metrics

CVSS 3.0 9.8/10CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Feb 19, 2018
Last modified
Jun 17, 2026
NVD status
Modified

Related CVEs from 2018

CVE-2018-72269.8An issue was discovered in vcSetXCutTextProc() in VNConsole.c in LinuxVNC and VNCommand from the LibVNC/vncterm distribution through 0.9.10.CVE-2018-72275.3A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow retrieviCVE-2018-72289.8A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow an unautCVE-2018-72299.8A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow an unautCVE-2018-72308.8A XML external entity (XXE) vulnerability exists in the import.cgi of the web interface component of the Schneider Electric's Pelco Sarix PrCVE-2018-72319.8A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow executioCVE-2018-72329.8A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow executioCVE-2018-72339.8A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow executioCVE-2018-72347.5A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow arbitrarCVE-2018-72357.5A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow arbitrarCVE-2018-72368.1A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could enable SSH serCVE-2018-72379.1A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow a remote
CVE-2018-7225: Critical severity, CVSS 9.8 | Vulnix