CVE-2018-7226

CriticalCVSS 9.8/10Last modified Jun 17, 2026

Description

An issue was discovered in vcSetXCutTextProc() in VNConsole.c in LinuxVNC and VNCommand from the LibVNC/vncterm distribution through 0.9.10. Missing sanitization of the client-specified message length may cause integer overflow or possibly have unspecified other impact via a specially crafted VNC packet.

Metrics

CVSS 3.0 9.8/10CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Feb 19, 2018
Last modified
Jun 17, 2026
NVD status
Modified

Related CVEs from 2018

CVE-2018-72275.3A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow retrieviCVE-2018-72289.8A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow an unautCVE-2018-72299.8A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow an unautCVE-2018-72308.8A XML external entity (XXE) vulnerability exists in the import.cgi of the web interface component of the Schneider Electric's Pelco Sarix PrCVE-2018-72319.8A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow executioCVE-2018-72329.8A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow executioCVE-2018-72339.8A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow executioCVE-2018-72347.5A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow arbitrarCVE-2018-72357.5A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow arbitrarCVE-2018-72368.1A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could enable SSH serCVE-2018-72379.1A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow a remoteCVE-2018-72389.8A buffer overflow vulnerability exist in the web-based GUI of Schneider Electric's Pelco Sarix Professional in all firmware versions prior t
CVE-2018-7226: Critical severity, CVSS 9.8 | Vulnix