CVE-2018-17914

CriticalCVSS 9.8/10Last modified Jun 17, 2026

Description

InduSoft Web Studio versions prior to 8.1 SP2, and InTouch Edge HMI (formerly InTouch Machine Edition) versions prior to 2017 SP2. This vulnerability could allow an unauthenticated user to remotely execute code with the same privileges as that of the InduSoft Web Studio or InTouch Edge HMI (formerly InTouch Machine Edition) runtime.

Metrics

CVSS 3.1 9.8/10CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Nov 2, 2018
Last modified
Jun 17, 2026
NVD status
Modified

Related CVEs from 2018

CVE-2018-179159.8All versions of Hangzhou Xiongmai Technology Co., Ltd XMeye P2P Cloud Server do not encrypt all device communication. This includes the XMeyCVE-2018-179169.8InduSoft Web Studio versions prior to 8.1 SP2, and InTouch Edge HMI (formerly InTouch Machine Edition) versions prior to 2017 SP2. A remote CVE-2018-179175.3All versions of Hangzhou Xiongmai Technology Co., Ltd XMeye P2P Cloud Server may allow an attacker to use MAC addresses to enumerate potentiCVE-2018-179189.8Circontrol CirCarLife all versions prior to 4.3.1, authentication to the device can be bypassed by entering the URL of a specific page.CVE-2018-179196.5All versions of Hangzhou Xiongmai Technology Co., Ltd XMeye P2P Cloud Server may allow an attacker to use an undocumented user account "defaCVE-2018-17927.8IBM WebSphere MQ 8.0.0.0 through 8.0.0.10, 9.0.0.0 through 9.0.0.5, 9.0.1 through 9.0.5, and 9.1.0.0 could allow a local user to inject codeCVE-2018-179218.8SAGA1-L8B with any firmware versions prior to A0.10 are vulnerable to an attack that may allow an attacker to force-pair the device without CVE-2018-179229.8Circontrol CirCarLife all versions prior to 4.3.1, the PAP credentials of the device are stored in clear text in a log file that is accessibCVE-2018-179236.9SAGA1-L8B with any firmware versions prior to A0.10 are vulnerable to an attack that an attacker with physical access to the product may ablCVE-2018-179248.6Rockwell Automation MicroLogix 1400 Controllers and 1756 ControlLogix Communications Modules An unauthenticated, remote threat actor could sCVE-2018-179254.8Multiple instances of this vulnerability (Unsafe ActiveX Control Marked Safe For Scripting) have been identified in the third-party ActiveX CVE-2018-179264.3The product M2M ETHERNET (FW Versions 2.22 and prior, ETH-FW Versions 1.01 and prior) is vulnerable in that an attacker can upload a malicio
CVE-2018-17914: Critical severity, CVSS 9.8 | Vulnix