CVE-2018-17924

HighCVSS 8.6/10Last modified Jun 17, 2026

Description

Rockwell Automation MicroLogix 1400 Controllers and 1756 ControlLogix Communications Modules An unauthenticated, remote threat actor could send a CIP connection request to an affected device, and upon successful connection, send a new IP configuration to the affected device even if the controller in the system is set to Hard RUN mode. When the affected device accepts this new IP configuration, a loss of communication occurs between the device and the rest of the system as the system traffic is still attempting to communicate with the device via the overwritten IP address.

Metrics

CVSS 3.1 8.6/10CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Dec 7, 2018
Last modified
Jun 17, 2026
NVD status
Modified

Related CVEs from 2018

CVE-2018-179254.8Multiple instances of this vulnerability (Unsafe ActiveX Control Marked Safe For Scripting) have been identified in the third-party ActiveX CVE-2018-179264.3The product M2M ETHERNET (FW Versions 2.22 and prior, ETH-FW Versions 1.01 and prior) is vulnerable in that an attacker can upload a malicioCVE-2018-179277.8In Delta Industrial Automation TPEditor, TPEditor Versions 1.90 and prior, multiple out-of-bounds write vulnerabilities may be exploited by CVE-2018-179286.5The product CMS-770 (Software Versions 1.7.1 and prior)is vulnerable that an attacker can read sensitive configuration files by bypassing thCVE-2018-179297.8In Delta Industrial Automation TPEditor, TPEditor Versions 1.90 and prior, multiple stack-based buffer overflow vulnerabilities may be exploCVE-2018-17936.1IBM WebSphere Application Server 7.0, 8.0, 8.5, and 9.0 using SAML ear is vulnerable to cross-site scripting. This vulnerability allows userCVE-2018-179309.8A stack-based buffer overflow vulnerability has been identified in Teledyne DALSA Sherlock Version 7.2.7.4 and prior, which may allow remoteCVE-2018-179316.8If an attacker has physical access to the VGo Robot (Versions 3.0.3.52164 and 3.0.3.53662. Prior versions may also be affected) they may be CVE-2018-179329.8JUUKO K-800 (Firmware versions prior to numbers ending ...9A, ...9B, ...9C, etc.) is vulnerable to a replay attack and command forgery, whicCVE-2018-179338.8VGo Robot (Versions 3.0.3.52164 and 3.0.3.53662. Prior versions may also be affected) connected to the VGo XAMPP. User accounts may be able CVE-2018-179349.8NUUO CMS All versions 3.3 and prior the application allows external input to construct a pathname that is able to be resolved outside the inCVE-2018-179358.1All versions of Telecrane F25 Series Radio Controls before 00.0A use fixed codes that are reproducible by sniffing and re-transmission. This
CVE-2018-17924: High severity, CVSS 8.6 | Vulnix