CVE-2017-7912

CriticalCVSS 9.8/10Last modified Jun 17, 2026

Description

Hanwha Techwin SRN-4000, SRN-4000 firmware versions prior to SRN4000_v2.16_170401, A specially crafted http request and response could allow an attacker to gain access to the device management page with admin privileges without proper authentication.

Metrics

CVSS 3.0 9.8/10CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Apr 8, 2019
Last modified
Jun 17, 2026
NVD status
Modified

Related CVEs from 2017

CVE-2017-79139.8A Plaintext Storage of a Password issue was discovered in Moxa OnCell G3110-HSPA Version 1.3 build 15082117 and previous versions, OnCell G3CVE-2017-79148.6A Missing Authorization issue was discovered in Rockwell Automation PanelView Plus 6 700-1500 6.00.04, 6.00.05, 6.00.42, 6.00-20140306, 6.10CVE-2017-79159.8An Improper Restriction of Excessive Authentication Attempts issue was discovered in Moxa OnCell G3110-HSPA Version 1.3 build 15082117 and pCVE-2017-79166.5A Permissions, Privileges, and Access Controls issue was discovered in ABB VSN300 WiFi Logger Card versions 1.8.15 and prior, and VSN300 WiFCVE-2017-79178.8A Cross-Site Request Forgery issue was discovered in Moxa OnCell G3110-HSPA Version 1.3 build 15082117 and previous versions, OnCell G3110-HCVE-2017-79186.8An Improper Access Control issue was discovered in Cambium Networks ePMP. After a valid user has used SNMP configuration export, an attackerCVE-2017-79199.8An Improper Authentication issue was discovered in Newport XPS-Cx and XPS-Qx. An attacker may bypass authentication by accessing a specific CVE-2017-79207.5An Improper Authentication issue was discovered in ABB VSN300 WiFi Logger Card versions 1.8.15 and prior, and VSN300 WiFi Logger Card for ReCVE-2017-79219.8An Improper Authentication issue was discovered in Hikvision DS-2CD2xx2F-I Series V5.2.0 build 140721 to V5.4.0 build 160530, DS-2CD2xx0F-I CVE-2017-79227.6An Improper Privilege Management issue was discovered in Cambium Networks ePMP. The privileges for SNMP community strings are not properly rCVE-2017-79238.8A Password in Configuration File issue was discovered in Hikvision DS-2CD2xx2F-I Series V5.2.0 build 140721 to V5.4.0 build 160530, DS-2CD2xCVE-2017-79247.5An Improper Input Validation issue was discovered in Rockwell Automation MicroLogix 1100 controllers 1763-L16BWA, 1763-L16AWA, 1763-L16BBB,
CVE-2017-7912: Critical severity, CVSS 9.8 | Vulnix