CVE-2017-7917

HighCVSS 8.8/10Last modified Jun 17, 2026

Description

A Cross-Site Request Forgery issue was discovered in Moxa OnCell G3110-HSPA Version 1.3 build 15082117 and previous versions, OnCell G3110-HSDPA Version 1.2 Build 09123015 and previous versions, OnCell G3150-HSDPA Version 1.4 Build 11051315 and previous versions, OnCell 5104-HSDPA, OnCell 5104-HSPA, and OnCell 5004-HSPA. The application does not sufficiently verify if a request was intentionally provided by the user who submitted the request, which could allow an attacker to modify the configuration of the device.

Metrics

CVSS 3.0 8.8/10CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
May 29, 2017
Last modified
Jun 17, 2026
NVD status
Modified

Related CVEs from 2017

CVE-2017-79186.8An Improper Access Control issue was discovered in Cambium Networks ePMP. After a valid user has used SNMP configuration export, an attackerCVE-2017-79199.8An Improper Authentication issue was discovered in Newport XPS-Cx and XPS-Qx. An attacker may bypass authentication by accessing a specific CVE-2017-79207.5An Improper Authentication issue was discovered in ABB VSN300 WiFi Logger Card versions 1.8.15 and prior, and VSN300 WiFi Logger Card for ReCVE-2017-79219.8An Improper Authentication issue was discovered in Hikvision DS-2CD2xx2F-I Series V5.2.0 build 140721 to V5.4.0 build 160530, DS-2CD2xx0F-I CVE-2017-79227.6An Improper Privilege Management issue was discovered in Cambium Networks ePMP. The privileges for SNMP community strings are not properly rCVE-2017-79238.8A Password in Configuration File issue was discovered in Hikvision DS-2CD2xx2F-I Series V5.2.0 build 140721 to V5.4.0 build 160530, DS-2CD2xCVE-2017-79247.5An Improper Input Validation issue was discovered in Rockwell Automation MicroLogix 1100 controllers 1763-L16BWA, 1763-L16AWA, 1763-L16BBB, CVE-2017-79259.8A Password in Configuration File issue was discovered in Dahua DH-IPC-HDBW23A0RN-ZS, DH-IPC-HDBW13A0SN, DH-IPC-HDW1XXX, DH-IPC-HDW2XXX, DH-ICVE-2017-79268.8A Cross-Site Request Forgery issue was discovered in OSIsoft PI Web API versions prior to 2017 (1.9.0). The vulnerability allows cross-site CVE-2017-79277.3A Use of Password Hash Instead of Password for Authentication issue was discovered in Dahua DH-IPC-HDBW23A0RN-ZS, DH-IPC-HDBW13A0SN, DH-IPC-CVE-2017-792810.0An Improper Access Control issue was discovered in Schweitzer Engineering Laboratories (SEL) SEL-3620 and SEL-3622 Security Gateway VersionsCVE-2017-79297.1An Absolute Path Traversal issue was discovered in Advantech WebAccess Version 8.1 and prior. The absolute path traversal vulnerability has