CVE-2017-7901

HighCVSS 8.6/10Last modified Jun 17, 2026

Description

A Predictable Value Range from Previous Values issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers 1763-L16AWA, Series A and B, Version 16.00 and prior versions; 1763-L16BBB, Series A and B, Version 16.00 and prior versions; 1763-L16BWA, Series A and B, Version 16.00 and prior versions; and 1763-L16DWD, Series A and B, Version 16.00 and prior versions and Allen-Bradley MicroLogix 1400 programmable logic controllers 1766-L32AWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWAA, Series A and B, Version 16.00 and prior versions; 1766-L32BXB, Series A and B, Version 16.00 and prior versions; 1766-L32BXBA, Series A and B, Version 16.00 and prior versions; and 1766-L32AWAA, Series A and B, Version 16.00 and prior versions. Insufficiently random TCP initial sequence numbers are generated, which may allow an attacker to predict the numbers from previous values. This may allow an attacker to spoof or disrupt TCP connections, resulting in a denial of service for the target device.

Metrics

CVSS 3.0 8.6/10CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:H

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Jun 30, 2017
Last modified
Jun 17, 2026
NVD status
Modified

Related CVEs from 2017

CVE-2017-79029.8A "Reusing a Nonce, Key Pair in Encryption" issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic conCVE-2017-79039.8A Weak Password Requirements issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers 1763-LCVE-2017-79059.8A Weak Cryptography for Passwords issue was discovered in General Electric (GE) Multilin SR 750 Feeder Protection Relay, firmware versions pCVE-2017-79068.8In ABB IP GATEWAY 3.39 and prior, the web server does not sufficiently verify that a request was performed by the authenticated user, which CVE-2017-79076.6An Improper XML Parser Configuration issue was discovered in Schneider Electric Wonderware Historian Client 2014 R2 SP1 and prior. An impropCVE-2017-79087.6A heap-based buffer overflow exists in the third-party product Gigasoft, v5 and prior, included in GE Communicator 3.15 and prior. A malicioCVE-2017-79099.8A Use of Client-Side Authentication issue was discovered in Advantech B+B SmartWorx MESR901 firmware versions 1.5.2 and prior. The web interCVE-2017-79107.5A Stack-Based Buffer Overflow issue was discovered in Digital Canal Structural Wind Analysis versions 9.1 and prior. An attacker may be ableCVE-2017-79118.8A Code Injection issue was discovered in CyberVision Kaa IoT Platform, Version 0.7.4. An insufficient-encapsulation vulnerability has been iCVE-2017-79129.8Hanwha Techwin SRN-4000, SRN-4000 firmware versions prior to SRN4000_v2.16_170401, A specially crafted http request and response could allowCVE-2017-79139.8A Plaintext Storage of a Password issue was discovered in Moxa OnCell G3110-HSPA Version 1.3 build 15082117 and previous versions, OnCell G3CVE-2017-79148.6A Missing Authorization issue was discovered in Rockwell Automation PanelView Plus 6 700-1500 6.00.04, 6.00.05, 6.00.42, 6.00-20140306, 6.10