CVE-2017-16728

HighCVSS 7.5/10Last modified Jun 17, 2026

Description

An Untrusted Pointer Dereference issue was discovered in Advantech WebAccess versions prior to 8.3. There are multiple vulnerabilities that may allow an attacker to cause the program to use an invalid memory address, resulting in a program crash.

Metrics

CVSS 3.0 7.5/10CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Jan 5, 2018
Last modified
Jun 17, 2026
NVD status
Modified

Related CVEs from 2017

CVE-2017-16736.1IBM Tivoli Key Lifecycle Manager 2.5, 2.6, and 2.7 is vulnerable to cross-site scripting. This vulnerability allows users to embed arbitraryCVE-2017-167318.8An Unprotected Transport of Credentials issue was discovered in ABB Ellipse 8.3 through Ellipse 8.9 released prior to December 2017 (includiCVE-2017-167326.5A use-after-free issue was discovered in Advantech WebAccess versions prior to 8.3. WebAccess allows an unauthenticated attacker to specify CVE-2017-167335.3A SQL Injection issue was discovered in Ecava IntegraXor v 6.1.1030.1 and prior. The SQL Injection vulnerability has been identified, which CVE-2017-167355.3A SQL Injection issue was discovered in Ecava IntegraXor v 6.1.1030.1 and prior. The SQL Injection vulnerability has been identified, which CVE-2017-167367.5An Unrestricted Upload Of File With Dangerous Type issue was discovered in Advantech WebAccess versions prior to 8.3. WebAccess allows a remCVE-2017-167377.8An issue was discovered in WECON Technology LEVI Studio HMI Editor v1.8.29 and prior. A specially-crafted malicious file may be able to causCVE-2017-167397.8An issue was discovered in WECON Technology LEVI Studio HMI Editor v1.8.29 and prior. Specially-crafted malicious files may be able to causeCVE-2017-1674010.0A Buffer Overflow issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1400 Controllers, Series B and C Versions 21.002 and CVE-2017-167415.3An Information Exposure issue was discovered in PHOENIX CONTACT FL SWITCH 3xxx, 4xxx, and 48xxx Series products running firmware Version 1.0CVE-2017-167439.8An Improper Authorization issue was discovered in PHOENIX CONTACT FL SWITCH 3xxx, 4xxx, and 48xxx Series products running firmware Version 1CVE-2017-167447.2A path traversal vulnerability in Tridium Niagara AX Versions 3.8 and prior and Niagara 4 systems Versions 4.4 and prior installed on Micros
CVE-2017-16728: High severity, CVSS 7.5 | Vulnix