CVE-2017-16737

HighCVSS 7.8/10Last modified Jun 17, 2026

Description

An issue was discovered in WECON Technology LEVI Studio HMI Editor v1.8.29 and prior. A specially-crafted malicious file may be able to cause a heap-based buffer overflow vulnerability when opened by a user.

Metrics

CVSS 3.0 7.8/10CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H

Weakness enumeration

Affected software

VendorProductVersions
n/aWECON Technology Co., Ltd. LeviStudio HMI EditorWECON Technology Co., Ltd. LeviStudio HMI Editor

References

Timeline

Published
Jan 12, 2018
Last modified
Jun 17, 2026
NVD status
Modified

Related CVEs from 2017

CVE-2017-167397.8An issue was discovered in WECON Technology LEVI Studio HMI Editor v1.8.29 and prior. Specially-crafted malicious files may be able to causeCVE-2017-1674010.0A Buffer Overflow issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1400 Controllers, Series B and C Versions 21.002 and CVE-2017-167415.3An Information Exposure issue was discovered in PHOENIX CONTACT FL SWITCH 3xxx, 4xxx, and 48xxx Series products running firmware Version 1.0CVE-2017-167439.8An Improper Authorization issue was discovered in PHOENIX CONTACT FL SWITCH 3xxx, 4xxx, and 48xxx Series products running firmware Version 1CVE-2017-167447.2A path traversal vulnerability in Tridium Niagara AX Versions 3.8 and prior and Niagara 4 systems Versions 4.4 and prior installed on MicrosCVE-2017-167457.8A Type Confusion issue was discovered in Delta Electronics Delta Industrial Automation Screen Editor, Version 2.00.23.00 or prior. An accessCVE-2017-167477.8An Out-of-bounds Write issue was discovered in Delta Electronics Delta Industrial Automation Screen Editor, Version 2.00.23.00 or prior. SpeCVE-2017-167489.8An attacker can log into the local Niagara platform (Niagara AX Framework Versions 3.8 and prior or Niagara 4 Framework Versions 4.4 and priCVE-2017-167497.8A Use-after-Free issue was discovered in Delta Electronics Delta Industrial Automation Screen Editor, Version 2.00.23.00 or prior. SpeciallyCVE-2017-167517.8A Stack-based Buffer Overflow issue was discovered in Delta Electronics Delta Industrial Automation Screen Editor, Version 2.00.23.00 or priCVE-2017-167537.5An Improper Input Validation issue was discovered in Advantech WebAccess versions prior to 8.3. WebAccess allows some inputs that may cause CVE-2017-167545.3Bolt before 3.3.6 does not properly restrict access to _profiler routes, related to EventListener/ProfilerListener.php and Provider/EventLis
CVE-2017-16737: High severity, CVSS 7.8 | Vulnix