CVE-2015-3956

CriticalCVSS 9.8/10Last modified Jun 17, 2026

Description

Hospira Plum A+ Infusion System version 13.4 and prior, Plum A+3 Infusion System version 13.6 and prior, and Symbiq Infusion System, version 3.13 and prior accept drug libraries, firmware updates, pump commands, and unauthorized configuration changes from unauthenticated devices on the host network. Hospira recommends that customers close Port 20/FTP and Port 23/TELNET on the affected devices. Hospira has also released the Plum 360 Infusion System which is not vulnerable to this issue.

Metrics

CVSS 3.0 9.8/10CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Mar 25, 2019
Last modified
Jun 17, 2026
NVD status
Modified

Related CVEs from 2015

CVE-2015-39574.6Hospira LifeCare PCA Infusion System before 7.0 stores private keys and certificates, which has unspecified impact and attack vectors.CVE-2015-39587.8Hospira LifeCare PCA Infusion System 5.0 and earlier, and possibly other versions, allows remote attackers to cause a denial of service (forCVE-2015-39597.2The firmware in MNS before 4.5.6 on Belden GarrettCom Magnum 6K and Magnum 10K switches has a hardcoded serial-console password for a privilCVE-2015-39604.3The firmware in MNS before 4.5.6 on Belden GarrettCom Magnum 6K and Magnum 10K switches uses hardcoded RSA private keys and certificates acrCVE-2015-39613.5The web-server component in MNS before 4.5.6 on Belden GarrettCom Magnum 6K and Magnum 10K switches allows remote authenticated users to cauCVE-2015-39625.0Schneider Electric StruxureWare Building Expert MPM before 2.15 does not use encryption for the client-server data stream, which allows remoCVE-2015-39635.8Wind River VxWorks before 5.5.1, 6.5.x through 6.7.x before 6.7.1.1, 6.8.x before 6.8.3, 6.9.x before 6.9.4.4, and 7.x before 7 ipnet_coreipCVE-2015-396410.0SMA Solar Sunny WebBox has hardcoded passwords, which makes it easier for remote attackers to obtain access via unspecified vectors.CVE-2015-39658.8Hospira Symbiq Infusion System 3.13 and earlier allows remote authenticated users to trigger "unanticipated operations" by leveraging "elevaCVE-2015-39664.0The IPsec SA establishment process on Innominate mGuard devices with firmware 8.x before 8.1.7 allows remote authenticated users to cause a CVE-2015-39676.8Cross-site request forgery (CSRF) vulnerability on Janitza UMG 508, 509, 511, 604, and 605 devices allows remote attackers to hijack the autCVE-2015-39687.5The FTP service on Janitza UMG 508, 509, 511, 604, and 605 devices has a default password, which makes it easier for remote attackers to rea
CVE-2015-3956: Critical severity, CVSS 9.8 | Vulnix