CVE-2015-3963

MediumCVSS 5.8/10Last modified Jun 17, 2026

Description

Wind River VxWorks before 5.5.1, 6.5.x through 6.7.x before 6.7.1.1, 6.8.x before 6.8.3, 6.9.x before 6.9.4.4, and 7.x before 7 ipnet_coreip 1.2.2.0, as used on Schneider Electric SAGE RTU devices before J2 and other devices, does not properly generate TCP initial sequence number (ISN) values, which makes it easier for remote attackers to spoof TCP sessions by predicting an ISN value.

Metrics

CVSS 2.0 5.8/10AV:N/AC:M/Au:N/C:N/I:P/A:P

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Aug 4, 2015
Last modified
Jun 17, 2026
NVD status
Modified

Related CVEs from 2015

CVE-2015-396410.0SMA Solar Sunny WebBox has hardcoded passwords, which makes it easier for remote attackers to obtain access via unspecified vectors.CVE-2015-39658.8Hospira Symbiq Infusion System 3.13 and earlier allows remote authenticated users to trigger "unanticipated operations" by leveraging "elevaCVE-2015-39664.0The IPsec SA establishment process on Innominate mGuard devices with firmware 8.x before 8.1.7 allows remote authenticated users to cause a CVE-2015-39676.8Cross-site request forgery (CSRF) vulnerability on Janitza UMG 508, 509, 511, 604, and 605 devices allows remote attackers to hijack the autCVE-2015-39687.5The FTP service on Janitza UMG 508, 509, 511, 604, and 605 devices has a default password, which makes it easier for remote attackers to reaCVE-2015-39695.0Janitza UMG 508, 509, 511, 604, and 605 devices allow remote attackers to obtain sensitive network-connection information via a request to UCVE-2015-39704.3Multiple cross-site scripting (XSS) vulnerabilities in the web interface on Janitza UMG 508, 509, 511, 604, and 605 devices allow remote attCVE-2015-39717.5The debug interface on Janitza UMG 508, 509, 511, 604, and 605 devices does not require authentication, which allows remote attackers to reaCVE-2015-397210.0The web interface on Janitza UMG 508, 509, 511, 604, and 605 devices supports only short PIN values for authentication, which makes it easieCVE-2015-39735.0Janitza UMG 508, 509, 511, 604, and 605 devices improperly generate session tokens, which makes it easier for remote attackers to determine CVE-2015-39749.0EasyIO EasyIO-30P-SF controllers with firmware before 0.5.21 and 2.x before 2.0.5.21, as used in Accutrol, Bar-Tech Automation, Infocon/EasyCVE-2015-39765.4Cross-site scripting (XSS) vulnerability in GE Multilink ML810/3000/3100 series switch 5.2.0 and earlier, and GE Multilink ML800/1200/1600/2
CVE-2015-3963: Medium severity, CVSS 5.8 | Vulnix