CVE-2026-82784

MediumCVSS 6.5/10Last modified Sep 16, 2026

Description

Missing authentication for critical function vulnerability exists in Remote I/O Coupler Unit (Server Type) CPSN-MCB271-*. An attacker may execute a REST API without authentication, which could allow the attacker to retrieve I/O values and/or control the output.

Metrics

CVSS 3.1 6.5/10CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Sep 14, 2026
Last modified
Sep 16, 2026
NVD status
Deferred

Related CVEs from 2026

CVE-2026-827854.3Stack-based buffer overflow vulnerability exists in Remote I/O Coupler Unit (Server Type) CPSN-MCB271-*. Receiving a specially crafted requeCVE-2026-827866.3Insufficiently protected credentials issue exists in Remote I/O Coupler Unit (Server Type) CPSN-MCB271-*. If this vulnerability is exploitedCVE-2026-827879.8Missing authentication for critical function vulnerability exists in CPSL-08P1EN. If this vulnerability is exploited, an affected product maCVE-2026-827886.1Cross-site scripting vulnerability exists in CPSL-08P1EN. If this vulnerability is exploited, an arbitrary script may be executed on a loggeCVE-2026-827898.8An improper neutralization of directives in dynamically evaluated code ('Eval Injection') issue exists in CONPROSYS HMI System(CHS). If explCVE-2026-82795.3The Masteriyo LMS plugin for WordPress is vulnerable to unauthorized data deletion due to a missing capability check on the 'delete_item_perCVE-2026-827905.4Cross-site scripting vulnerability exists in PC-HELPER Wireless I/O DIO-0404RY-LWF and PC-HELPER Wireless I/O DIO-0404RY-LWF-US. If this vulCVE-2026-827918.8Improper neutralization of special elements used in an OS command ('OS Command Injection') issue exists in Contec CAN 2.0B Communication WirCVE-2026-827925.2Cross-site scripting vulnerability exists in Contec CAN 2.0B Communication Wireless LAN / USB Converter Unit. If this vulnerability is exploCVE-2026-827937.2Unrestricted upload of file with dangerous type issue exists in Contec CAN 2.0B Communication Wireless LAN / USB Converter Unit. If a speciaCVE-2026-827948.8SolarView Compact contains an OS command Injection vulnerability in in Schedule Settings. If this vulnerability is exploited, an arbitrary OCVE-2026-827955.4SolarView Compact contains a cross-site scripting vulnerability in Schedule Settings and Mail Send Setting. If this vulnerability is exploit
CVE-2026-82784: Medium severity, CVSS 6.5 | Vulnix