CVE-2026-80156

CriticalCVSS 9.1/10Last modified Sep 24, 2026

Description

Lantronix SLC8000 before firmware v9.7.0.5, SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882/SLCx-03/SLCx-02 contain a path traversal vulnerability in the web management portal upload endpoint that allows authenticated attackers to write arbitrary data to any location on the device's filesystem, leading to remote code execution. The upload filename validation strips backslash characters but does not subsequently check for forward slashes when a backslash is detected; by supplying a filename containing both characters an attacker writes outside the intended upload directory to any writable path. Attackers can use this vulnerability to achieve complete loss of confidentiality, integrity, and availability on the affected device and potentially impact downstream serial-connected devices.

Metrics

CVSS 3.1 9.1/10CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H

Weakness enumeration

Affected software

Source: the vendor's advisory (CNA). NVD analysis pending.

No affected versions have been published.

Timeline

Published
Sep 22, 2026
Last modified
Sep 24, 2026
NVD status
Awaiting Analysis

Related CVEs from 2026

CVE-2026-801585.5A flaw was found in the ipa_getkeytab module of the community.general Ansible collection. The module's bind_pw parameter, used to supply theCVE-2026-801594.0Acrobat Reader is affected by an Untrusted Search Path vulnerability that could result in privilege escalation. An attacker with high privilCVE-2026-80168.8Use after free in WebRTC in Google Chrome prior to 148.0.7778.96 allowed a remote attacker to execute arbitrary code inside a sandbox via a CVE-2026-801605.5Acrobat Reader is affected by an out-of-bounds read vulnerability that could lead to disclosure of sensitive memory. An attacker could leverCVE-2026-801617.8Acrobat Reader is affected by an Access of Resource Using Incompatible Type ('Type Confusion') vulnerability that could result in arbitrary CVE-2026-801625.5Acrobat Reader is affected by a Use After Free vulnerability that could lead to disclosure of sensitive memory. An attacker could leverage tCVE-2026-801649.1Dell SCG 5.0 Appliance versions prior to 5.36.00.16 and Dell SCG 5.0 Application versions prior to 5.36.00.00, contains an Improper CertificCVE-2026-801667.8Dell SCG 5.0 Appliance versions prior to 5.36.00.16 and Dell SCG 5.0 Application versions prior to 5.36.00.00, contains an Improper PrivilegCVE-2026-801675.5Dell SCG 5.0 Appliance versions prior to 5.36.00.16 and Dell SCG 5.0 Application versions prior to 5.36.00.00, contains an Use of Hard-codedCVE-2026-801693.3Dell SCG 5.0 Appliance versions prior to 5.36.00.16 and Dell SCG 5.0 Application versions prior to 5.36.00.00, contains an Insertion of SensCVE-2026-80173.1Side-channel information leakage in Media in Google Chrome prior to 148.0.7778.96 allowed a remote attacker to leak cross-origin data via a CVE-2026-801706.5Dell SCG 5.0 Appliance versions prior to 5.36.00.16 and Dell SCG 5.0 Application versions prior to 5.36.00.00, contains an Use of Hard-coded
CVE-2026-80156: Critical severity, CVSS 9.1 | Vulnix