CVE-2026-79957

HighCVSS 8.1/10Last modified Oct 16, 2026

Description

ServiceNext contains an insecure direct object reference (IDOR) in the /api/Usuario/GetUsuarios endpoint, which accepts a user-controlled numeric ID in the request body without verifying that the authenticated token belongs to the requested account (CWE-639). Any authenticated user can iterate the ID parameter to retrieve the full profile record of every other user, including passwords stored in cleartext (CWE-256), enabling account takeover and credential-stuffing attacks.

Metrics

CVSS 3.1 8.1/10CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Oct 14, 2026
Last modified
Oct 16, 2026
NVD status
Deferred

Related CVEs from 2026

CVE-2026-799596.8The Botslab G980H dash camera firmware contains a hard-coded root account password that cannot be changed by the user. An attacker who obtaiCVE-2026-79964.2Insufficient validation of untrusted input in SSL in Google Chrome prior to 148.0.7778.96 allowed a remote attacker who had compromised the CVE-2026-799607.1When a push was authenticated with a deploy key, Gitea recorded the repository owner as the pusher, so permission checks in the push hook piCVE-2026-799615.3Dell SCG 5.0 Appliance versions prior to 5.36.00.16 and Dell SCG 5.0 Application versions prior to 5.36.00.00, contains a Missing AuthenticaCVE-2026-799625.9Dell SCG 5.0 Appliance versions prior to 5.36.00.16 and Dell SCG 5.0 Application versions prior to 5.36.00.00, contains a Concurrent ExecutiCVE-2026-799637.4Dell SCG 5.0 Appliance versions prior to 5.36.00.16 and Dell SCG 5.0 Application versions prior to 5.36.00.00, contains a Download of Code WCVE-2026-799645.3Dell SCG 5.0 Appliance versions prior to 5.36.00.16 and Dell SCG 5.0 Application versions prior to 5.36.00.00, contains an Improper NeutraliCVE-2026-799655.3Dell SCG 5.0 Appliance versions prior to 5.36.00.16 and Dell SCG 5.0 Application versions prior to 5.36.00.00, contains an External Control CVE-2026-799663.3Dell SCG 5.0 Appliance versions prior to 5.36.00.16 and Dell SCG 5.0 Application versions prior to 5.36.00.00, contains an Insertion of SensCVE-2026-799675.6Dell SCG 5.0 Appliance versions prior to 5.36.00.16 and Dell SCG 5.0 Application versions prior to 5.36.00.00, contains an Improper CertificCVE-2026-799685.9Dell SCG 5.0 Appliance versions prior to 5.36.00.16 and Dell SCG 5.0 Application versions prior to 5.36.00.00, contains a Time-of-check TimeCVE-2026-799695.9Dell SCG 5.0 Appliance versions prior to 5.36.00.16 and Dell SCG 5.0 Application versions prior to 5.36.00.00, contains a Concurrent Executi
CVE-2026-79957: High severity, CVSS 8.1 | Vulnix