CVE-2026-78003

CriticalCVSS 9.8/10Last modified Oct 12, 2026

Description

The Mailgun for WordPress plugin for WordPress is vulnerable to Server-Side Request Forgery (SSRF) via path traversal in versions up to and including 2.2.0. This is due to insufficient input validation in the add_list() function, which accepts user-controlled array keys from $_POST['addresses'], passes them through sanitize_text_field(). This makes it possible for unauthenticated attackers to make authenticated POST requests to any Mailgun API endpoint using the WordPress site's API key, including creating inbound email-forwarding routes that can intercept password reset emails, leading to administrator account takeover.

Metrics

CVSS 3.1 9.8/10CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Aug 22, 2026
Last modified
Oct 12, 2026
NVD status
Deferred

Related CVEs from 2026

CVE-2026-780069.8The The Events Calendar plugin for WordPress is vulnerable to Remote Code Execution in all versions up to, and including, 6.17.4 via the is_CVE-2026-780088.6A buffer overflow vulnerability in the WatchGuard Fireware OS Management Web UI allows an authenticated administrator with network access toCVE-2026-780098.7An out-of-bounds read vulnerability in the WatchGuard Fireware OS iked process allows a remote unauthenticated attacker to create a Denial oCVE-2026-780108.7A stack-based buffer overflow vulnerability in the WatchGuard Fireware OS iked process iallows a remote unauthenticated attacker to create aCVE-2026-780118.7An integer underflow vulnerability in the WatchGuard Fireware OS iked process allows a remote unauthenticated attacker to create a Denial ofCVE-2026-780129.8An issue in the NetStaX EtherNet/IP Stack prior to v5.6.1 could allow a large Class 3 explicit-message request to exceed the application-sidCVE-2026-780136.3Dell Secure Connect Gateway (SCG) Policy Manager, versions prior to 5.34.00.16, contains an Initialization of a Resource with an Insecure DeCVE-2026-780155.3Dell Secure Connect Gateway (SCG) Policy Manager, versions prior to 5.34.00.16, contains an Use of Less Trusted Source vulnerability. An unaCVE-2026-780164.3Dell Secure Connect Gateway (SCG) Policy Manager, versions prior to 5.34.00.16, contains an Improper Validation of Specified Type of Input vCVE-2026-780173.8Dell Secure Connect Gateway (SCG) Policy Manager, versions prior to 5.34.00.16, contains an Improper Check for Unusual or Exceptional ConditCVE-2026-780187.1Dell Secure Connect Gateway (SCG) Policy Manager, versions prior to 5.34.00.16, contains an Initialization of a Resource with an Insecure DeCVE-2026-780198.8Dell Secure Connect Gateway (SCG) Policy Manager, versions prior to 5.34.00.16, contains an Inclusion of Functionality from Untrusted Contro
CVE-2026-78003: Critical severity, CVSS 9.8 | Vulnix