CVE-2026-71931

HighCVSS 7.2/10Last modified Oct 12, 2026

Description

Multiple DrayTek VigorSwitch models contain a command injection vulnerability in the tftp_upgrade function. The vulnerability is caused by insufficient filtering before the filename field is concatenated into a command. A remote attacker can trigger this vulnerability via crafted input to execute arbitrary commands with root privileges. Exploitation requires valid administrative credentials for the device's web management interface.

Metrics

CVSS 3.1 7.2/10CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H

Weakness enumeration

Affected software

VendorProductVersions
DrayTek CorporationVigorSwitch G2540xs< 3.9.10
DrayTek CorporationVigorSwitch P2540xs< 3.9.10
DrayTek CorporationVigorSwitch FX2120< 3.9.10
DrayTek CorporationVigorSwitch G2282x< 2.10.6
DrayTek CorporationVigorSwitch P2282x< 2.10.6
DrayTek CorporationVigorSwitch Q2300x< 2.10.7
DrayTek CorporationVigorSwitch PQ2300xb< 2.10.7
DrayTek CorporationVigorSwitch G2542x< 3.10.6
DrayTek CorporationVigorSwitch P2542x< 3.10.6
DrayTek CorporationVigorSwitch P2542xh< 3.10.6
DrayTek CorporationVigorSwitch PX2060< 2.9.10
DrayTek CorporationVigorSwitch G1280< 2.9.10
DrayTek CorporationVigorSwitch P1280< 2.9.10
DrayTek CorporationVigorSwitch P1281x< 2.9.10
DrayTek CorporationVigorSwitch G1282< 2.9.10
DrayTek CorporationVigorSwitch P1282< 2.9.10
DrayTek CorporationVigorSwitch G2121< 2.9.10
DrayTek CorporationVigorSwitch P2121< 2.9.10
DrayTek CorporationVigorSwitch PQ2121x< 2.9.10
DrayTek CorporationVigorSwitch Q2121x< 2.9.10
DrayTek CorporationVigorSwitch G2280x< 2.9.10
DrayTek CorporationVigorSwitch P2280x< 2.9.10
DrayTek CorporationVigorSwitch Q2200x< 2.9.10
DrayTek CorporationVigorSwitch PQ2200xb< 2.9.10
DrayTek CorporationVigorSwitch G2100< 2.9.10
DrayTek CorporationVigorSwitch P2100< 2.9.10
DrayTek CorporationVigorSwitch G2540x< 2.9.10
DrayTek CorporationVigorSwitch P2540x< 2.9.10

References

Timeline

Published
Aug 24, 2026
Last modified
Oct 12, 2026
NVD status
Deferred

Related CVEs from 2026

CVE-2026-719324.9Multiple DrayTek VigorSwitch models contain a directory traversal vulnerability in the getSyslogFile function. The vulnerability is caused bCVE-2026-719339.1Multiple DrayTek VigorSwitch models contain unauthorized operation vulnerabilities in multiple syslog functions. The vulnerability is causedCVE-2026-719347.2Multiple DrayTek VigorSwitch models contain a buffer overflow vulnerability in the pingtrace function. The vulnerability is caused by missinCVE-2026-719357.2Multiple DrayTek VigorSwitch models contain a buffer overflow vulnerability in the webBackupAction function. The vulnerability is caused by CVE-2026-719367.2Multiple DrayTek VigorSwitch models contain a buffer overflow vulnerability in the sysreboot function. The vulnerability is caused by unsafeCVE-2026-719377.2Multiple DrayTek VigorSwitch models contain a buffer overflow vulnerability in the poe_schedule_profile function. The vulnerability is causeCVE-2026-719387.2Multiple DrayTek VigorSwitch models contain a buffer overflow vulnerability in the switch_lan_gvrp function. The vulnerability is caused by CVE-2026-719397.2Multiple DrayTek VigorSwitch models contain a buffer overflow vulnerability in the acl_general_setup Add ACE function. The vulnerability is CVE-2026-71947.3A weakness has been identified in SourceCodester Pharmacy Sales and Inventory System 1.0. This impacts an unknown function of the file /ajaxCVE-2026-719407.2Multiple DrayTek VigorSwitch models contain a buffer overflow vulnerability in the acl_general_setup Edit ACE function. The vulnerability isCVE-2026-719417.2Multiple DrayTek VigorSwitch models contain a buffer overflow vulnerability in the diag_logmail function. The vulnerability is caused by conCVE-2026-719427.2Multiple DrayTek VigorSwitch models contain a buffer overflow vulnerability in the mail_mailalert function. The vulnerability is caused by c
CVE-2026-71931: High severity, CVSS 7.2 | Vulnix