Description
A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 6). The affected application uses a password hashing implementation with a static, hardcoded salt shared across all users and installations, and is configured with an insufficient number of iterations. This could allow an attacker to efficiently recover user passwords using brute-force or precomputed attacks, potentially resulting in unauthorized access.
Metrics
CVSS 3.1 9.8/10
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:HWeakness enumeration
Affected software
| Vendor | Product | Versions |
|---|---|---|
| Siemens | SINEC INS | < V1.0 SP2 Update 6 |
References
Timeline
- Published
- Jun 9, 2026
- Last modified
- Oct 23, 2026
- NVD status
- Analyzed