CVE-2026-37234

HighCVSS 8.2/10Last modified Jul 22, 2026

Description

FlexRIC v2.0.0 allows a single SCTP connection to bind multiple xapp_ids by sending multiple E42_SETUP_REQUESTs. On disconnect, only the first registered xapp_id's resources are cleaned up; subsequent xapp_ids and their subscriptions remain as stale entries. A remote attacker can exploit this to leak subscription state in the iApp, potentially causing resource exhaustion or state corruption over time.

Metrics

CVSS 3.1 8.2/10CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:H

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Jun 1, 2026
Last modified
Jul 22, 2026
NVD status
Analyzed

Related CVEs from 2026

CVE-2026-372357.5FlexRIC v2.0.0 trusts the xapp_id field from E42 message payloads without binding it to the sender's SCTP association. The validation functiCVE-2026-372369.8grpc-gateway v2.28.0 is vulnerable to Incorrect Access Control. The application processes the X-HTTP-Method-Override header in ServeMux.ServCVE-2026-372377.5vLLM up to and including 0.17.0 allows remote attackers to cause a Denial of Service via memory exhaustion. The AsyncMediaIO.fetch_audio andCVE-2026-37248.8A weakness has been identified in SourceCodester Patients Waiting Area Queue Management System 1.0. This impacts an unknown function of the CVE-2026-37258.8A flaw has been found in 1024-lab/lab1024 SmartAdmin up to 3.29. Affected by this issue is the function freemarkerResolverContent of the filCVE-2026-37268.8A vulnerability has been found in Tenda F453 1.0.0.3. This affects the function fromwebExcptypemanFilter of the file /goform/webExcptypemanFCVE-2026-372668.0An issue in Responsive File Manager Responsive FileManager Version 9.14.0 allows a remote attacker to execute arbitrary code via the force_dCVE-2026-37278.8A vulnerability was found in Tenda F453 1.0.0.3. This vulnerability affects the function sub_3C6C0 of the file /goform/QuickIndex. The manipCVE-2026-372709.8Trueview Security camera T18161- AF v4.9.60.0 contains an authentication bypass vulnerability caused by improper password validation and theCVE-2026-372719.8Fire-Boltt Smartwatch FB BGS001 Firmware: MOY-JS14-2.0.4 is vulnerable to Improper Authentication, The device accepts GATT Write Request comCVE-2026-37288.8A vulnerability was determined in Tenda F453 1.0.0.3/1.If. This issue affects the function fromSetCfm of the file /goform/setcfm. This manipCVE-2026-372819.8An OS command injection vulnerability in the /stream-to-vlc Express route in hitarth-gg Zenshin before 2.7.0 allows remote attackers to exec
CVE-2026-37234: High severity, CVSS 8.2 | Vulnix