CVE-2026-37232

HighCVSS 8.6/10Last modified Jul 22, 2026

Description

An issue was discovered in OpenAirInterface5G 2.4.0 (nr-softmodem) in the E2SM-KPM RAN Function's PRB utilization metric calculation. The functions fill_RRU_PrbTotDl() and fill_RRU_PrbTotUl() in openair2/E2AP/RAN_FUNCTION/O-RAN/ran_func_kpm_subs.c (lines 182 and 197) compute PRB usage percentages by dividing by the difference of two consecutive total_prb_aggregate samples without checking for zero. When a malicious xApp sends a high volume of E42_RIC_SUBSCRIPTION_REQUESTs via the FlexRIC iApp (port 36422/SCTP), the E2 Agent generates KPM Indication reports at high frequency. If two consecutive sampling intervals yield identical PRB aggregate values, the divisor becomes zero, triggering SIGFPE and crashing the entire 5G base station process (nr-softmodem). This results in complete 5G cell service interruption for all connected UEs. No authentication is required.

Metrics

CVSS 3.1 8.6/10CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Jun 1, 2026
Last modified
Jul 22, 2026
NVD status
Analyzed

Related CVEs from 2026

CVE-2026-372337.5FlexRIC v2.0.0 contains an authorization bypass in the iApp's xApp isolation mechanism. The equality function eq_xapp_ric_gen_id() in src/riCVE-2026-372348.2FlexRIC v2.0.0 allows a single SCTP connection to bind multiple xapp_ids by sending multiple E42_SETUP_REQUESTs. On disconnect, only the firCVE-2026-372357.5FlexRIC v2.0.0 trusts the xapp_id field from E42 message payloads without binding it to the sender's SCTP association. The validation functiCVE-2026-372369.8grpc-gateway v2.28.0 is vulnerable to Incorrect Access Control. The application processes the X-HTTP-Method-Override header in ServeMux.ServCVE-2026-372377.5vLLM up to and including 0.17.0 allows remote attackers to cause a Denial of Service via memory exhaustion. The AsyncMediaIO.fetch_audio andCVE-2026-37248.8A weakness has been identified in SourceCodester Patients Waiting Area Queue Management System 1.0. This impacts an unknown function of the CVE-2026-37258.8A flaw has been found in 1024-lab/lab1024 SmartAdmin up to 3.29. Affected by this issue is the function freemarkerResolverContent of the filCVE-2026-37268.8A vulnerability has been found in Tenda F453 1.0.0.3. This affects the function fromwebExcptypemanFilter of the file /goform/webExcptypemanFCVE-2026-372668.0An issue in Responsive File Manager Responsive FileManager Version 9.14.0 allows a remote attacker to execute arbitrary code via the force_dCVE-2026-37278.8A vulnerability was found in Tenda F453 1.0.0.3. This vulnerability affects the function sub_3C6C0 of the file /goform/QuickIndex. The manipCVE-2026-372709.8Trueview Security camera T18161- AF v4.9.60.0 contains an authentication bypass vulnerability caused by improper password validation and theCVE-2026-372719.8Fire-Boltt Smartwatch FB BGS001 Firmware: MOY-JS14-2.0.4 is vulnerable to Improper Authentication, The device accepts GATT Write Request com
CVE-2026-37232: High severity, CVSS 8.6 | Vulnix